Determination of the Antiretroviral Drug Lamivudine: by Potentiometric Titration using All Solid State Graphite Based Iodide Selective Electrode

 
9783846528778: Determination of the Antiretroviral Drug Lamivudine: by Potentiometric Titration using All Solid State Graphite Based Iodide Selective Electrode
View all copies of this ISBN edition:
 
 

A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our Laboratory.The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions.

"synopsis" may belong to another edition of this title.

About the Author:

I am a highly enthusiastic professional always trying hard to fulfill my goals to grow professionally and spritually which is indispensable for the well being of human kind. born and grown up in a beautiful town Bahirdar, Ethiopia. Currently i am a lecturer in analytical chemistry,at one of the oldest universities in Ethiopia, Haremaya university.

"About this title" may belong to another edition of this title.

Buy New View Book
List Price: US$ 68.00
US$ 46.25

Convert currency

Shipping: US$ 9.62
From United Kingdom to U.S.A.

Destination, rates & speeds

Add to Basket

Top Search Results from the AbeBooks Marketplace

1.

Shemsia Mohamed Hudie (author)
Published by LAP Lambert Academic Publishing 2011-10-24 (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New paperback Quantity Available: > 20
Seller:
Blackwell's
(Oxford, OX, United Kingdom)
Rating
[?]

Book Description LAP Lambert Academic Publishing 2011-10-24, 2011. paperback. Condition: New. Seller Inventory # 9783846528778

More information about this seller | Contact this seller

Buy New
US$ 46.25
Convert currency

Add to Basket

Shipping: US$ 9.62
From United Kingdom to U.S.A.
Destination, rates & speeds

2.

Hudie, Shemsia Mohamed / Moges, Ghirma
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Quantity Available: 1
Seller:
Rating
[?]

Book Description Condition: New. Publisher/Verlag: LAP Lambert Academic Publishing | by Potentiometric Titration using All Solid State Graphite Based Iodide Selective Electrode | A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our Laboratory.The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions. | Format: Paperback | Language/Sprache: english | 60 pp. Seller Inventory # K9783846528778

More information about this seller | Contact this seller

Buy New
US$ 52.75
Convert currency

Add to Basket

Shipping: US$ 3.19
From Germany to U.S.A.
Destination, rates & speeds

3.

Hudie, Shemsia Mohamed
Published by LAP Lambert Academic Publishing (2016)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Paperback Quantity Available: 1
Print on Demand
Seller:
Ria Christie Collections
(Uxbridge, United Kingdom)
Rating
[?]

Book Description LAP Lambert Academic Publishing, 2016. Paperback. Condition: New. PRINT ON DEMAND Book; New; Publication Year 2016; Not Signed; Fast Shipping from the UK. No. book. Seller Inventory # ria9783846528778_lsuk

More information about this seller | Contact this seller

Buy New
US$ 59.11
Convert currency

Add to Basket

Shipping: US$ 4.97
From United Kingdom to U.S.A.
Destination, rates & speeds

4.

Shemsia Mohamed Hudie
Published by LAP Lambert Academic Publishing (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Quantity Available: > 20
Print on Demand
Seller:
Books2Anywhere
(Fairford, GLOS, United Kingdom)
Rating
[?]

Book Description LAP Lambert Academic Publishing, 2011. PAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # LQ-9783846528778

More information about this seller | Contact this seller

Buy New
US$ 54.39
Convert currency

Add to Basket

Shipping: US$ 11.55
From United Kingdom to U.S.A.
Destination, rates & speeds

5.

Shemsia Mohamed Hudie
Published by LAP Lambert Academic Publishing (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Quantity Available: > 20
Print on Demand
Seller:
Paperbackshop-US
(Wood Dale, IL, U.S.A.)
Rating
[?]

Book Description LAP Lambert Academic Publishing, 2011. PAP. Condition: New. New Book. Shipped from US within 10 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # IQ-9783846528778

More information about this seller | Contact this seller

Buy New
US$ 64.25
Convert currency

Add to Basket

Shipping: US$ 3.99
Within U.S.A.
Destination, rates & speeds

6.

Shemsia Mohamed Hudie
Published by LAP Lambert Acad. Publ. Nov 2011 (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Taschenbuch Quantity Available: 1
Seller:
BuchWeltWeit Inh. Ludwig Meier e.K.
(Bergisch Gladbach, Germany)
Rating
[?]

Book Description LAP Lambert Acad. Publ. Nov 2011, 2011. Taschenbuch. Condition: Neu. Neuware - A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our Laboratory.The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions. 60 pp. Englisch. Seller Inventory # 9783846528778

More information about this seller | Contact this seller

Buy New
US$ 57.63
Convert currency

Add to Basket

Shipping: US$ 19.56
From Germany to U.S.A.
Destination, rates & speeds

7.

Shemsia Mohamed Hudie
Published by LAP Lambert Acad. Publ. Nov 2011 (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Taschenbuch Quantity Available: 1
Seller:
Rheinberg-Buch
(Bergisch Gladbach, Germany)
Rating
[?]

Book Description LAP Lambert Acad. Publ. Nov 2011, 2011. Taschenbuch. Condition: Neu. Neuware - A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our Laboratory.The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions. 60 pp. Englisch. Seller Inventory # 9783846528778

More information about this seller | Contact this seller

Buy New
US$ 57.63
Convert currency

Add to Basket

Shipping: US$ 19.56
From Germany to U.S.A.
Destination, rates & speeds

8.

Shemsia Mohamed Hudie, Ghirma Moges
Published by LAP Lambert Academic Publishing, Germany (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Paperback Quantity Available: 1
Seller:
The Book Depository EURO
(London, United Kingdom)
Rating
[?]

Book Description LAP Lambert Academic Publishing, Germany, 2011. Paperback. Condition: New. Aufl.. Language: English . Brand New Book. A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our Laboratory.The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions. Seller Inventory # KNV9783846528778

More information about this seller | Contact this seller

Buy New
US$ 86.42
Convert currency

Add to Basket

Shipping: US$ 3.84
From United Kingdom to U.S.A.
Destination, rates & speeds

9.

Shemsia Mohamed Hudie
Published by LAP Lambert Acad. Publ. Nov 2011 (2011)
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Taschenbuch Quantity Available: 1
Print on Demand
Seller:
AHA-BUCH GmbH
(Einbeck, Germany)
Rating
[?]

Book Description LAP Lambert Acad. Publ. Nov 2011, 2011. Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Neuware - A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57.57 mV/decade which reasonably agreed with early data from our Laboratory.The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions. 60 pp. Englisch. Seller Inventory # 9783846528778

More information about this seller | Contact this seller

Buy New
US$ 57.63
Convert currency

Add to Basket

Shipping: US$ 33.68
From Germany to U.S.A.
Destination, rates & speeds

10.

Shemsia Mohamed Hudie
Published by LAP Lambert Academic Publishing
ISBN 10: 3846528773 ISBN 13: 9783846528778
New Paperback Quantity Available: > 20
Seller:
BuySomeBooks
(Las Vegas, NV, U.S.A.)
Rating
[?]

Book Description LAP Lambert Academic Publishing. Paperback. Condition: New. 60 pages. Dimensions: 8.7in. x 5.9in. x 0.1in.A solid-state iodide selective electrode with Ag2S-AgI adsorbed on graphite rod, recovered from a dry cell, was prepared and validated for its typical response characteristics with an objective to develop a potentiometric titration system for rapid measurements of Lamuvidine (LMV) in tablets used as an antiretroviral drug for Hepatis B and HIV patients. The partial validationexhibited typical response values of linear range of 10-6 to 10-1 M iodide and a slope 57. 57 mVdecade which reasonably agreed with early data from our Laboratory. The basis of LMV determination is its oxidation by excess bromine generated from bromate-bromide mixture. The unreacted bromine oxidized the added excess iodide to iodine. The amount of bromine consumed by LMV, the basis of its determination, was determined by subtracting the back-titrated iodine with thiosulphate whose end-point was located potentiometrically with the solid state iodide selective electrode against a reference electrode. The iodometric back titration provided for the indirect determination of 1-30 mg LMV in turbid tablet test solutions. This item ships from multiple locations. Your book may arrive from Roseburg,OR, La Vergne,TN. Paperback. Seller Inventory # 9783846528778

More information about this seller | Contact this seller

Buy New
US$ 96.96
Convert currency

Add to Basket

Shipping: FREE
Within U.S.A.
Destination, rates & speeds