Selected ion flow tube mass spectrometry (SIFT-MS) is a chromatography-free, direct-analysis technique that is ideally suited to real-time, quantitative analysis of volatile compounds in air at trace concentrations. SIFT-MS utilises highly controlled, soft chemical ionisation – in the form of gas-phase ion–molecule reactions – coupled with mass spectrometry detection to provide both broad-spectrum and specific analysis of volatiles with diverse functionalities.
This book provides readers with a broad understanding of the principles of the SIFT-MS technique and how it differs from conventional chromatographic approaches that are used for analysis of volatiles. It will also aid users to identify existing and new methods where adoption of SIFT-MS would be advantageous, e.g. through reduction in sample preparation or higher throughput, and provides the knowledge and insight required to develop best-practice methods and effectively evaluate the data that they generate and approaches to optimising, validating, and transferring methods to routine analysis and other applications.
This book addresses two needs for SIFT-MS users:
The audience for this book is method developers and laboratory technicians engaged in routine analysis and research laboratories, but it is also well suited to graduate students, reducing the mentoring load for academics and research fellows.
"synopsis" may belong to another edition of this title.
Mark Perkins is a senior applications chemist at Element Materials Technology Laboratory Instrumentation in Cambridge, United Kingdom (formerly Anatune), and a global authority in automated SIFT-MS. Dr Perkins has extensive experience in both conventional chromatographic methods as well as SIFT-MS. Prior to joining Anatune in 2015, he spent 12 years as a senior analyst and chromatography section manager at the Malaysian Rubber Board’s UK research centre, working on regulated pharmaceutical applications within a GMP environment.
Vaughan Langford obtained BSc(Hons) and PhD degrees in chemistry at the University of Canterbury (Christchurch, New Zealand) in 1993 and 1997, respectively. He then completed postdoctoral research fellowships at the Universities of Geneva (Switzerland) and Western Australia (Perth, Australia). He moved from optical spectroscopy to SIFT-MS upon taking up a postdoctoral fellowship at the University of Canterbury in late 2002. The commencement of this fellowship coincided with the founding of Syft Technologies where Dr Langford has worked ever since. He has extensive experience in SIFT-MS application and method development plus data interpretation. Additionally, from 2005 to 2018 he managed a small contract testing service using SIFT-MS, from sample analysis through to reporting and quality assurance. Dr Langford is active in providing SIFT-MS training (both in the science and application) and publishing in the literature on the diverse applications of SIFT-MS (40 peer-reviewed publications, including 9 book chapters and reviews).
"About this title" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 50559871-n
Seller: INDOO, Avenel, NJ, U.S.A.
Condition: New. Seller Inventory # 9781837674602
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 50559871
Seller: Rarewaves.com USA, London, LONDO, United Kingdom
Paperback. Condition: New. Selected ion flow tube mass spectrometry (SIFT-MS) is a chromatography-free, direct-analysis technique that is ideally suited to real-time, quantitative analysis of volatile compounds in air at trace concentrations. SIFT-MS utilises highly controlled, soft chemical ionisation - in the form of gas-phase ion-molecule reactions - coupled with mass spectrometry detection to provide both broad-spectrum and specific analysis of volatiles with diverse functionalities.This book provides readers with a broad understanding of the principles of the SIFT-MS technique and how it differs from conventional chromatographic approaches that are used for analysis of volatiles. It will also aid users to identify existing and new methods where adoption of SIFT-MS would be advantageous, e.g. through reduction in sample preparation or higher throughput, and provides the knowledge and insight required to develop best-practice methods and effectively evaluate the data that they generate and approaches to optimising, validating, and transferring methods to routine analysis and other applications.This book addresses two needs for SIFT-MS users:As a reference work, it gathers the fundamental principles from the literature and laboratory experience to provide a practical textbook for those using SIFT-MS in routine laboratories, research organisations and academia.It utilises a procedure-based approach to apply principles to routine analysis, simplifying implementation in routine analysis laboratories, while also accelerating effective application in other specialisations.The audience for this book is method developers and laboratory technicians engaged in routine analysis and research laboratories, but it is also well suited to graduate students, reducing the mentoring load for academics and research fellows. Seller Inventory # LU-9781837674602
Quantity: Over 20 available
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. gld edition. 338 pages. 9.20x6.14 inches. In Stock. Seller Inventory # __1837674604
Quantity: 2 available
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In English. Seller Inventory # ria9781837674602_new
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 50559871-n
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 50559871
Quantity: Over 20 available
Seller: Rarewaves.com UK, London, United Kingdom
Paperback. Condition: New. Selected ion flow tube mass spectrometry (SIFT-MS) is a chromatography-free, direct-analysis technique that is ideally suited to real-time, quantitative analysis of volatile compounds in air at trace concentrations. SIFT-MS utilises highly controlled, soft chemical ionisation - in the form of gas-phase ion-molecule reactions - coupled with mass spectrometry detection to provide both broad-spectrum and specific analysis of volatiles with diverse functionalities.This book provides readers with a broad understanding of the principles of the SIFT-MS technique and how it differs from conventional chromatographic approaches that are used for analysis of volatiles. It will also aid users to identify existing and new methods where adoption of SIFT-MS would be advantageous, e.g. through reduction in sample preparation or higher throughput, and provides the knowledge and insight required to develop best-practice methods and effectively evaluate the data that they generate and approaches to optimising, validating, and transferring methods to routine analysis and other applications.This book addresses two needs for SIFT-MS users:As a reference work, it gathers the fundamental principles from the literature and laboratory experience to provide a practical textbook for those using SIFT-MS in routine laboratories, research organisations and academia.It utilises a procedure-based approach to apply principles to routine analysis, simplifying implementation in routine analysis laboratories, while also accelerating effective application in other specialisations.The audience for this book is method developers and laboratory technicians engaged in routine analysis and research laboratories, but it is also well suited to graduate students, reducing the mentoring load for academics and research fellows. Seller Inventory # LU-9781837674602
Quantity: Over 20 available