This book addresses several issues related to the metrological characterization of high-performance pulsed power converters. Initially, a background and state-of-the-art on measurement systems for high-performance power converter are presented. In industrial applications of power converters metrology, specifications are often given in terms of worst-case uncertainty (WCU). Therefore, an analytical model for predicting the WCU of a measurement system is discussed and detailed for instruments affected by Gaussian noise. The authors discuss the study and design of a reference acquisition system for characterizing high-power pulses as well as the design of an on-line acquisition system for controlling the power converter. The book continues with numerical results obtained in simulation for the three main topics, which demonstrate the effectiveness of the proposals. Finally, the experimental results of a case study, carried out in the framework of the Compact Linear Collider (CLIC) at CERN, are reported. To meet CLIC requirements the two systems were designed to be ultra-low noise and are demonstrated to be repeatable in the order of few tens of parts per million (ppm).
"synopsis" may belong to another edition of this title.
Professor, University of Napoli Federico II, Naples, Italy
"About this title" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 31783561-n
Seller: BargainBookStores, Grand Rapids, MI, U.S.A.
Paperback or Softback. Condition: New. High-Repeatability Data Acquisition Systems for Pulsed Power Converters. Book. Seller Inventory # BBS-9781946646224
Seller: Rarewaves USA, OSWEGO, IL, U.S.A.
Paperback. Condition: New. Addresses several issues related to the metrological characterization of high-performance pulsed power converters. Initially, a background and state-of-the-art on measurement systems for high-performance power converter are presented. In industrial applications of power converters metrology, specifications are often given in terms of worst-case uncertainty (WCU). Therefore, an analytical model for predicting the WCU of a measurement system is discussed and detailed for instruments affected by Gaussian noise. The authors discuss the study and design of a reference acquisition system for characterizing high-power pulses as well as the design of an on-line acquisition system for controlling the power converter. The book continues with numerical results obtained in simulation for the three main topics, which demonstrate the effectiveness of the proposals. Finally, the experimental results of a case study, carried out in the framework of the Compact Linear Collider (CLIC) at CERN, are reported. To meet CLIC requirements the two systems were designed to be ultra-low noise and are demonstrated to be repeatable in the order of few tens of parts per million (ppm). Seller Inventory # LU-9781946646224
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Seller Inventory # I-9781946646224
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 31783561
Seller: Rarewaves.com USA, London, LONDO, United Kingdom
Paperback. Condition: New. Addresses several issues related to the metrological characterization of high-performance pulsed power converters. Initially, a background and state-of-the-art on measurement systems for high-performance power converter are presented. In industrial applications of power converters metrology, specifications are often given in terms of worst-case uncertainty (WCU). Therefore, an analytical model for predicting the WCU of a measurement system is discussed and detailed for instruments affected by Gaussian noise. The authors discuss the study and design of a reference acquisition system for characterizing high-power pulses as well as the design of an on-line acquisition system for controlling the power converter. The book continues with numerical results obtained in simulation for the three main topics, which demonstrate the effectiveness of the proposals. Finally, the experimental results of a case study, carried out in the framework of the Compact Linear Collider (CLIC) at CERN, are reported. To meet CLIC requirements the two systems were designed to be ultra-low noise and are demonstrated to be repeatable in the order of few tens of parts per million (ppm). Seller Inventory # LU-9781946646224
Quantity: Over 20 available
Seller: Brook Bookstore On Demand, Napoli, NA, Italy
Condition: new. Seller Inventory # ZMIBUDU4OZ
Quantity: Over 20 available
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # FW-9781946646224
Quantity: 15 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 31783561-n
Quantity: Over 20 available
Seller: THE SAINT BOOKSTORE, Southport, United Kingdom
Paperback / softback. Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Seller Inventory # C9781946646224
Quantity: Over 20 available