Excessive post construction and differential settlements constitute engineering challenges for structure founded on soft cohesive soil which caused instability and crack to the existing structure. Inadequacy of design for foundation supporting structure during the early stage of construction and less information on site investigation might be the main reason for this problem. Polyurethane (PU) injection pile is proposed to replace the conventional underpinning pile. No excavation is required and only a small diameter of hole is drilled on the existing slab foundation before injection of PU. Analyses of the settlement problem and design of the remedial measures using PU injection pile were carried out using Two-Dimensional (2-D) finite element method (FEM) analyses. The sophisticated FEM is necessary because of the complexity of soil-structure interaction problem, involving subsoil-pile-slab-fill and vice versa.
"synopsis" may belong to another edition of this title.
Diana Che Lat is a lecturer in Geotechnical Engineering at Universiti Teknologi Mara, Malaysia. She has over 5 years experience as a Geotechnical Engineer at the leading Geotechnical Consultant Firm in Malaysia. Her consultancy works ranged from site investigations, soil testing,soft ground improvement, hill site development, highway and pavement.
"About this title" may belong to another edition of this title.
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26405870955
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Seller Inventory # 407283380
Quantity: 4 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Excessive post construction and differential settlements constitute engineering challenges for structure founded on soft cohesive soil which caused instability and crack to the existing structure. Inadequacy of design for foundation supporting structure during the early stage of construction and less information on site investigation might be the main reason for this problem. Polyurethane (PU) injection pile is proposed to replace the conventional underpinning pile. No excavation is required and only a small diameter of hole is drilled on the existing slab foundation before injection of PU. Analyses of the settlement problem and design of the remedial measures using PU injection pile were carried out using Two-Dimensional (2-D) finite element method (FEM) analyses. The sophisticated FEM is necessary because of the complexity of soil-structure interaction problem, involving subsoil-pile-slab-fill and vice versa. 68 pp. Englisch. Seller Inventory # 9783330067820
Quantity: 2 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND. Seller Inventory # 18405870945
Quantity: 4 available
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. 68 pages. 8.66x5.91x0.16 inches. In Stock. Seller Inventory # 3330067829
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Che Lat DianaDiana Che Lat is a lecturer in Geotechnical Engineering at Universiti Teknologi Mara, Malaysia. She has over 5 years experience as a Geotechnical Engineer at the leading Geotechnical Consultant Firm in Malaysia. Her cons. Seller Inventory # 151236000
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Excessive post construction and differential settlements constitute engineering challenges for structure founded on soft cohesive soil which caused instability and crack to the existing structure. Inadequacy of design for foundation supporting structure during the early stage of construction and less information on site investigation might be the main reason for this problem. Polyurethane (PU) injection pile is proposed to replace the conventional underpinning pile. No excavation is required and only a small diameter of hole is drilled on the existing slab foundation before injection of PU. Analyses of the settlement problem and design of the remedial measures using PU injection pile were carried out using Two-Dimensional (2-D) finite element method (FEM) analyses. The sophisticated FEM is necessary because of the complexity of soil-structure interaction problem, involving subsoil-pile-slab-fill and vice versa.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 68 pp. Englisch. Seller Inventory # 9783330067820
Quantity: 1 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Excessive post construction and differential settlements constitute engineering challenges for structure founded on soft cohesive soil which caused instability and crack to the existing structure. Inadequacy of design for foundation supporting structure during the early stage of construction and less information on site investigation might be the main reason for this problem. Polyurethane (PU) injection pile is proposed to replace the conventional underpinning pile. No excavation is required and only a small diameter of hole is drilled on the existing slab foundation before injection of PU. Analyses of the settlement problem and design of the remedial measures using PU injection pile were carried out using Two-Dimensional (2-D) finite element method (FEM) analyses. The sophisticated FEM is necessary because of the complexity of soil-structure interaction problem, involving subsoil-pile-slab-fill and vice versa. Seller Inventory # 9783330067820
Quantity: 1 available
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Finite Element Analysis of Polyurethane Injection Pile | Two-Dimensional (2-D) Finite Element Method (FEM) Analyses of Soil-structure Interaction Complexity | Diana Che Lat (u. a.) | Taschenbuch | 68 S. | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783330067820 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Seller Inventory # 108945510
Quantity: 5 available