Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collector current density in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distributed corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers.
"synopsis" may belong to another edition of this title.
Albert W. Yuen, Ph.D.: Engineering studies and graduate research at University of Western Australia. 40 years of experience in utility construction and operations in Australia and in China. From 2003 to 2006 conducted research on electrostatic precipitators at University of New South Wales. Senior Consultant at Fujian Longking Company Ltd, China.
"About this title" may belong to another edition of this title.
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # L0-9783639007909
Seller: Rarewaves.com USA, London, LONDO, United Kingdom
Paperback. Condition: New. Seller Inventory # LU-9783639007909
Quantity: Over 20 available
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # L0-9783639007909
Quantity: Over 20 available
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Seller Inventory # I-9783639007909
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In English. Seller Inventory # ria9783639007909_new
Quantity: Over 20 available
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collec-tor current density in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distri-buted corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collector current density in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distributed corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Seller Inventory # 9783639007909
Quantity: 1 available
Seller: moluna, Greven, Germany
Kartoniert / Broschiert. Condition: New. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector elec. Seller Inventory # 4948832
Quantity: Over 20 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. Neuware - Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collector current density in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distributed corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. Seller Inventory # 9783639007909
Quantity: 2 available
Seller: Rarewaves.com UK, London, United Kingdom
Paperback. Condition: New. Seller Inventory # LU-9783639007909
Quantity: Over 20 available
Seller: Buchpark, Trebbin, Germany
Condition: Sehr gut. Zustand: Sehr gut | Sprache: Englisch | Produktart: Bücher | Keine Beschreibung verfügbar. Seller Inventory # 4476862/2
Quantity: 1 available