A grid connected photovoltaic (PV) system is taken, in which a storage device is used as a backup source. The energy storage system is used to make the intermittent PV power more dispatchable and stable. Here, the storage device is mainly taken as Ni-MH(Nickel metal hydride) battery, as it is more convenient to use in high power applications such as solar and wind systems because of its low cost and availability in large size. Finally the active power, reactive power, PCC current and PCC voltage is compared during the line to ground fault so that the performance comparison can be done in case of PV system and BESS based PV system to investigate that after the fault occurrence how faster the system returns to stable position from the unstable position. Hence it is found that in the BESS system based PV system the proposed controller acts better as compared to that of the PV system only.
"synopsis" may belong to another edition of this title.
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26387375960
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand. Seller Inventory # 392256647
Quantity: 4 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A grid connected photovoltaic (PV) system is taken, in which a storage device is used as a backup source. The energy storage system is used to make the intermittent PV power more dispatchable and stable. Here, the storage device is mainly taken as Ni-MH(Nickel metal hydride) battery, as it is more convenient to use in high power applications such as solar and wind systems because of its low cost and availability in large size. Finally the active power, reactive power, PCC current and PCC voltage is compared during the line to ground fault so that the performance comparison can be done in case of PV system and BESS based PV system to investigate that after the fault occurrence how faster the system returns to stable position from the unstable position. Hence it is found that in the BESS system based PV system the proposed controller acts better as compared to that of the PV system only. 84 pp. Englisch. Seller Inventory # 9783659352850
Quantity: 1 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND. Seller Inventory # 18387375954
Quantity: 4 available
Seller: moluna, Greven, Germany
Condition: New. Seller Inventory # 385766480
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A grid connected photovoltaic (PV) system is taken, in which a storage device is used as a backup source. The energy storage system is used to make the intermittent PV power more dispatchable and stable. Here, the storage device is mainly taken as Ni-MH(Nickel metal hydride) battery, as it is more convenient to use in high power applications such as solar and wind systems because of its low cost and availability in large size. Finally the active power, reactive power, PCC current and PCC voltage is compared during the line to ground fault so that the performance comparison can be done in case of PV system and BESS based PV system to investigate that after the fault occurrence how faster the system returns to stable position from the unstable position. Hence it is found that in the BESS system based PV system the proposed controller acts better as compared to that of the PV system only.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 84 pp. Englisch. Seller Inventory # 9783659352850
Quantity: 1 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A grid connected photovoltaic (PV) system is taken, in which a storage device is used as a backup source. The energy storage system is used to make the intermittent PV power more dispatchable and stable. Here, the storage device is mainly taken as Ni-MH(Nickel metal hydride) battery, as it is more convenient to use in high power applications such as solar and wind systems because of its low cost and availability in large size. Finally the active power, reactive power, PCC current and PCC voltage is compared during the line to ground fault so that the performance comparison can be done in case of PV system and BESS based PV system to investigate that after the fault occurrence how faster the system returns to stable position from the unstable position. Hence it is found that in the BESS system based PV system the proposed controller acts better as compared to that of the PV system only. Seller Inventory # 9783659352850
Quantity: 1 available