This is a simple analogical approach to calculate the reactive power by using proposed method of power flow analysis in the transmission line. The MATLAB is used for power flow analysis and identified the unhealthy bus of a power system. The microcontroller is used for sensing the voltage level of the transmission line. The thyristor controlled reactor and thyristor switched capacitor are used for voltage control where switching control of thyristor is managed by microcontroller by providing appropriate gate pulse according to the condition of the transmission line.
"synopsis" may belong to another edition of this title.
Md. Ruhul Amin was born in Bangladesh. He has completed B.Sc. in Electrical and Electronic Engineering (EEE) from University of Information Technology and Sciences (UITS)’2012, Dhaka. Now he is working as a Lecturer of EEE at UITS, Dhaka. His research interests are SmartGrid, HVDC, Power Electronics, FACTS, Distributed & Hybrid Generation & Contro
"About this title" may belong to another edition of this title.
Shipping:
US$ 32.48
From United Kingdom to U.S.A.
Shipping:
US$ 25.90
From Germany to U.S.A.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This is a simple analogical approach to calculate the reactive power by using proposed method of power flow analysis in the transmission line. The MATLAB is used for power flow analysis and identified the unhealthy bus of a power system. The microcontroller is used for sensing the voltage level of the transmission line. The thyristor controlled reactor and thyristor switched capacitor are used for voltage control where switching control of thyristor is managed by microcontroller by providing appropriate gate pulse according to the condition of the transmission line. 136 pp. Englisch. Seller Inventory # 9783659395529
Quantity: 2 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This is a simple analogical approach to calculate the reactive power by using proposed method of power flow analysis in the transmission line. The MATLAB is used for power flow analysis and identified the unhealthy bus of a power system. The microcontroller is used for sensing the voltage level of the transmission line. The thyristor controlled reactor and thyristor switched capacitor are used for voltage control where switching control of thyristor is managed by microcontroller by providing appropriate gate pulse according to the condition of the transmission line. Seller Inventory # 9783659395529
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Seller Inventory # 5153440
Quantity: Over 20 available
Seller: Mispah books, Redhill, SURRE, United Kingdom
Paperback. Condition: Like New. Like New. book. Seller Inventory # ERICA79736593955286
Quantity: 1 available