The effect on a shell-side convective heat transfer coefficient (h) [W/m.k] is investigated using the CFD code FLUENT, with variation in a longitudinal pitch to diameter ratio, SL, in the range of 1.15 to 2.6 with a fixed transverse pitch to diameter ratio. For a benchmark purpose, typical thermal-hydraulic conditions for the Zukauskas correlation are assumed. Many sensitivity calculations for different mesh sizes and turbulent models are performed to check the accuracy of the numerical solution. As a result of the turbulence sensitivity study, for the staggered tube bank case, the Realizable κ-ε turbulence model was found to be in good agreement with the results of the Zukauskas correlation among the other investigated turbulence models. On the other hand, for the inline tube bank case, the SST κ-ω turbulence model predicted the average heat transfer coefficient better than the ε-based turbulence models
"synopsis" may belong to another edition of this title.
Mr. Ashraf Alfandi was born in Ramtha - Jordan. He has a BSc and MSc in Nuclear Engineering. Currently he's working as a nuclear engineer at Jordan Research and Training Reactor. His research interest is performing thermal hydraulic system modeling and computational fluid dynamics simulation of complex fluid flows in nuclear reactor systems.
"About this title" may belong to another edition of this title.
Shipping:
US$ 26.08
From Germany to U.S.A.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The effect on a shell-side convective heat transfer coefficient (h) [W/m.k] is investigated using the CFD code FLUENT, with variation in a longitudinal pitch to diameter ratio, SL, in the range of 1.15 to 2.6 with a fixed transverse pitch to diameter ratio. For a benchmark purpose, typical thermal-hydraulic conditions for the Zukauskas correlation are assumed. Many sensitivity calculations for different mesh sizes and turbulent models are performed to check the accuracy of the numerical solution. As a result of the turbulence sensitivity study, for the staggered tube bank case, the Realizable - turbulence model was found to be in good agreement with the results of the Zukauskas correlation among the other investigated turbulence models. On the other hand, for the inline tube bank case, the SST - turbulence model predicted the average heat transfer coefficient better than the -based turbulence models 88 pp. Englisch. Seller Inventory # 9783659905902
Quantity: 2 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The effect on a shell-side convective heat transfer coefficient (h) [W/m.k] is investigated using the CFD code FLUENT, with variation in a longitudinal pitch to diameter ratio, SL, in the range of 1.15 to 2.6 with a fixed transverse pitch to diameter ratio. For a benchmark purpose, typical thermal-hydraulic conditions for the Zukauskas correlation are assumed. Many sensitivity calculations for different mesh sizes and turbulent models are performed to check the accuracy of the numerical solution. As a result of the turbulence sensitivity study, for the staggered tube bank case, the Realizable - turbulence model was found to be in good agreement with the results of the Zukauskas correlation among the other investigated turbulence models. On the other hand, for the inline tube bank case, the SST - turbulence model predicted the average heat transfer coefficient better than the -based turbulence models. Seller Inventory # 9783659905902
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Alfandi AshrafMr. Ashraf Alfandi was born in Ramtha - Jordan. He has a BSc and MSc in Nuclear Engineering. Currently he s working as a nuclear engineer at Jordan Research and Training Reactor. His research interest is performing ther. Seller Inventory # 385770525
Quantity: Over 20 available
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. 88 pages. 8.66x5.91x0.20 inches. In Stock. Seller Inventory # 3659905909
Quantity: 1 available