Items related to Design and Analysis of Mechatronics System: A Case...

Design and Analysis of Mechatronics System: A Case Study for Handling Hazardous gases for Chemical Industry - Softcover

 
9783659944635: Design and Analysis of Mechatronics System: A Case Study for Handling Hazardous gases for Chemical Industry

Synopsis

The present automation system comes in to existence through its various stages. In the past, System is done through relay and contactor logics. Since the human intervention is more, the scope of errors was also more. But with the advent of microprocessors several new tools as PLC’s, SCADA and DCS come in to use. These have reduced human intervention, which in turn has increased accuracy, precision and efficiency. This case study deals with the incidental release of toxic chlorine gas from the chlorine charging station to chlorine reactor in colour pigment manufacturing industry. The probable causes of the accidents are due to manual handling of toxic gases. The analysis and design of system is to be done identify the possible errors and the unsafe activities and take safe preventive measures. It is a great opportunity to learn and design a safer plant in the future. The used toxic gases are controlled by Programmable logic Controller (PLC) using Integrated Mechatronics approach for the automation of processes.

"synopsis" may belong to another edition of this title.

About the Author

Er.Rajkumar H. Patil is working as Manager Engineering at Sempertrans India Pvt. Ltd., Roha , Dist: Raigad, Maharastra. Prof. S.N.Teli is working as Professor in Mechanical Engineering at Saraswati College of Engineering Kharghar– NaviMumbai. Mr.Hrushikesh Sawant is working as Lecturer at Abdul Razzak Kalsekar Polytechnic,Panvel-NaviMumbai.

"About this title" may belong to another edition of this title.

Search results for Design and Analysis of Mechatronics System: A Case...

Seller Image

Rajkumar Patil
ISBN 10: 3659944637 ISBN 13: 9783659944635
New Taschenbuch
Print on Demand

Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The present automation system comes in to existence through its various stages. In the past, System is done through relay and contactor logics. Since the human intervention is more, the scope of errors was also more. But with the advent of microprocessors several new tools as PLC's, SCADA and DCS come in to use. These have reduced human intervention, which in turn has increased accuracy, precision and efficiency. This case study deals with the incidental release of toxic chlorine gas from the chlorine charging station to chlorine reactor in colour pigment manufacturing industry. The probable causes of the accidents are due to manual handling of toxic gases. The analysis and design of system is to be done identify the possible errors and the unsafe activities and take safe preventive measures. It is a great opportunity to learn and design a safer plant in the future. The used toxic gases are controlled by Programmable logic Controller (PLC) using Integrated Mechatronics approach for the automation of processes. 100 pp. Englisch. Seller Inventory # 9783659944635

Contact seller

Buy New

US$ 60.49
Convert currency
Shipping: US$ 27.07
From Germany to U.S.A.
Destination, rates & speeds

Quantity: 2 available

Add to basket

Seller Image

Rajkumar Patil|S.N. Teli|Hrushikesh Sawant
Published by LAP LAMBERT Academic Publishing, 2016
ISBN 10: 3659944637 ISBN 13: 9783659944635
New Softcover
Print on Demand

Seller: moluna, Greven, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Patil RajkumarEr.Rajkumar H. Patil is working as Manager Engineering at Sempertrans India Pvt. Ltd., Roha , Dist: Raigad, Maharastra. Prof. S.N.Teli is working as Professor in Mechanical Engineering at Saraswati College of Engineerin. Seller Inventory # 158878032

Contact seller

Buy New

US$ 50.56
Convert currency
Shipping: US$ 57.66
From Germany to U.S.A.
Destination, rates & speeds

Quantity: Over 20 available

Add to basket

Seller Image

Rajkumar Patil
ISBN 10: 3659944637 ISBN 13: 9783659944635
New Taschenbuch

Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Taschenbuch. Condition: Neu. Neuware -The present automation system comes in to existence through its various stages. In the past, System is done through relay and contactor logics. Since the human intervention is more, the scope of errors was also more. But with the advent of microprocessors several new tools as PLC¿s, SCADA and DCS come in to use. These have reduced human intervention, which in turn has increased accuracy, precision and efficiency. This case study deals with the incidental release of toxic chlorine gas from the chlorine charging station to chlorine reactor in colour pigment manufacturing industry. The probable causes of the accidents are due to manual handling of toxic gases. The analysis and design of system is to be done identify the possible errors and the unsafe activities and take safe preventive measures. It is a great opportunity to learn and design a safer plant in the future. The used toxic gases are controlled by Programmable logic Controller (PLC) using Integrated Mechatronics approach for the automation of processes.Books on Demand GmbH, Überseering 33, 22297 Hamburg 100 pp. Englisch. Seller Inventory # 9783659944635

Contact seller

Buy New

US$ 60.49
Convert currency
Shipping: US$ 70.61
From Germany to U.S.A.
Destination, rates & speeds

Quantity: 2 available

Add to basket

Seller Image

Rajkumar Patil
Published by LAP LAMBERT Academic Publishing, 2016
ISBN 10: 3659944637 ISBN 13: 9783659944635
New Taschenbuch
Print on Demand

Seller: AHA-BUCH GmbH, Einbeck, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The present automation system comes in to existence through its various stages. In the past, System is done through relay and contactor logics. Since the human intervention is more, the scope of errors was also more. But with the advent of microprocessors several new tools as PLC's, SCADA and DCS come in to use. These have reduced human intervention, which in turn has increased accuracy, precision and efficiency. This case study deals with the incidental release of toxic chlorine gas from the chlorine charging station to chlorine reactor in colour pigment manufacturing industry. The probable causes of the accidents are due to manual handling of toxic gases. The analysis and design of system is to be done identify the possible errors and the unsafe activities and take safe preventive measures. It is a great opportunity to learn and design a safer plant in the future. The used toxic gases are controlled by Programmable logic Controller (PLC) using Integrated Mechatronics approach for the automation of processes. Seller Inventory # 9783659944635

Contact seller

Buy New

US$ 60.49
Convert currency
Shipping: US$ 71.60
From Germany to U.S.A.
Destination, rates & speeds

Quantity: 1 available

Add to basket

Stock Image

Rajkumar Patil
Published by LAP LAMBERT Academic Publishing, 2016
ISBN 10: 3659944637 ISBN 13: 9783659944635
New Paperback

Seller: Revaluation Books, Exeter, United Kingdom

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Paperback. Condition: Brand New. 100 pages. 8.66x5.91x0.23 inches. In Stock. Seller Inventory # 3659944637

Contact seller

Buy New

US$ 100.77
Convert currency
Shipping: US$ 33.88
From United Kingdom to U.S.A.
Destination, rates & speeds

Quantity: 1 available

Add to basket