The penetration of Distributed Generation (DG) changes the fault current level and direction. This leads to violate the relay coordination in the power system network. Superconducting fault current limiters (SFCLs) are commonly used to minimise the fault current level to restore original relay coordination. In this book optimum location of the SFCL to limit the fault current level with minimum size and cost of SFCL. The restoration of protection coordination is carried out without changing the original relay settings or disconnecting DG from power system network during fault conditions. In this work, a restive type SFCL is presented to minimise the fault current level. A typical power system model including generation, transmission and distribution network with DG is presented to determine the optimum location and the performance of the SFCL. Three phase faults are simulated at different locations in the power system and the effect of DG of fault current is evaluated. Accordingly, the optimum arrangement of the SFCL location in power system with DG has been proposed.
"synopsis" may belong to another edition of this title.
Tushar Deokar completed his master of engineering in electrical power system. He is currently working as assistant professor in electrical department of S.B. Patil College of Engineering Pune, Maharashtra, India. His research topic is to find the optimal location of super conducting fault current limiter to mitigate distribution generation impact.
"About this title" may belong to another edition of this title.
Shipping:
US$ 25.08
From Germany to U.S.A.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The penetration of Distributed Generation (DG) changes the fault current level and direction. This leads to violate the relay coordination in the power system network. Superconducting fault current limiters (SFCLs) are commonly used to minimise the fault current level to restore original relay coordination. In this book optimum location of the SFCL to limit the fault current level with minimum size and cost of SFCL. The restoration of protection coordination is carried out without changing the original relay settings or disconnecting DG from power system network during fault conditions. In this work, a restive type SFCL is presented to minimise the fault current level. A typical power system model including generation, transmission and distribution network with DG is presented to determine the optimum location and the performance of the SFCL. Three phase faults are simulated at different locations in the power system and the effect of DG of fault current is evaluated. Accordingly, the optimum arrangement of the SFCL location in power system with DG has been proposed. 72 pp. Englisch. Seller Inventory # 9786135819939
Quantity: 2 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The penetration of Distributed Generation (DG) changes the fault current level and direction. This leads to violate the relay coordination in the power system network. Superconducting fault current limiters (SFCLs) are commonly used to minimise the fault current level to restore original relay coordination. In this book optimum location of the SFCL to limit the fault current level with minimum size and cost of SFCL. The restoration of protection coordination is carried out without changing the original relay settings or disconnecting DG from power system network during fault conditions. In this work, a restive type SFCL is presented to minimise the fault current level. A typical power system model including generation, transmission and distribution network with DG is presented to determine the optimum location and the performance of the SFCL. Three phase faults are simulated at different locations in the power system and the effect of DG of fault current is evaluated. Accordingly, the optimum arrangement of the SFCL location in power system with DG has been proposed. Seller Inventory # 9786135819939
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Deokar TusharTushar Deokar completed his master of engineering in electrical power system. He is currently working as assistant professor in electrical department of S.B. Patil College of Engineering Pune, Maharashtra, India. His re. Seller Inventory # 385844333
Quantity: Over 20 available
Seller: dsmbooks, Liverpool, United Kingdom
paperback. Condition: New. New. book. Seller Inventory # D8S0-3-M-6135819933-6
Quantity: 1 available