Shipping:
US$ 25.40
From Germany to U.S.A.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Protection scheme of a radial network fails in coordination when additional power source is provided to the network via distributed generator other than a single source of power. Trans Amadi, 33 kV radial distribution network in Port Harcourt, Nigeria, has manually operated isolators backing up circuit breakers at substation. This arrangement alone cannot overcome rising issues due to bidirectional/multidirectional flow of power in a radial network whenever distributed generators are connected. There is therefore, a need for a protection scheme to be adopted whose devices can 'coordinate' as well as offer a reliable protection to the network. This book proposes a protection scheme design using coordinated behaviours of relay-operated reclosers and sectionalizers, as well as manages the effect distributed generators has, in a radial network using fault current limiter. Proposed protection scheme shows results of a good coordination, mis-cordination and an improved coordination, without distributed generator, with distributed generator and with a fault current limiter respectively. 84 pp. Englisch. Seller Inventory # 9786137320853
Quantity: 2 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Protection scheme of a radial network fails in coordination when additional power source is provided to the network via distributed generator other than a single source of power. Trans Amadi, 33 kV radial distribution network in Port Harcourt, Nigeria, has manually operated isolators backing up circuit breakers at substation. This arrangement alone cannot overcome rising issues due to bidirectional/multidirectional flow of power in a radial network whenever distributed generators are connected. There is therefore, a need for a protection scheme to be adopted whose devices can 'coordinate' as well as offer a reliable protection to the network. This book proposes a protection scheme design using coordinated behaviours of relay-operated reclosers and sectionalizers, as well as manages the effect distributed generators has, in a radial network using fault current limiter. Proposed protection scheme shows results of a good coordination, mis-cordination and an improved coordination, without distributed generator, with distributed generator and with a fault current limiter respectively. Seller Inventory # 9786137320853
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Osabohien RotimiRotimi Wiliams Osabohien has a first degree in electrical engineering in the University of Nigeria, Nsukka and a master degree in the University of Port Harcourt, all in Nigeria. Research area include power system wit. Seller Inventory # 385844826
Quantity: Over 20 available