A new method was established for the determination of extractable flame retardants from textile, foam, leather and plastic test specimens. The flame retardants were extracted with toluene from test specimens using ultrasonic assisted extraction with extraction time of 60 min at 60 ºC. Flame retardants were separated on a DB-XLB column using gas chromatography mass spectrometry (GC-MS) with helium (99.9 %) as carrier gas. One target and two qualifier ions were selected for target analyte under SIM/SCAN mode. Pre-treatment parameters were optimized, including the type of extractant, extraction method and extraction time. Under optimized conditions, recoveries of target compounds ranged from 90 to 100.8 %. Calibration curve working range was 0.25 to 5.0 mg L-1 with regression value 0.996-0.998. Relative standard deviation (RSD) was <15% for test specimens and <10% for pure standards respectively. Limit of detections (LODs) were lower than 0.02 mg L-1 level. The proposed method was successfully used for the determination of actual specimens with concentrations ranging from 1.20 to 18.34 mg L-1.
"synopsis" may belong to another edition of this title.
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # L2-9786208433581
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Seller Inventory # I-9786208433581
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # L2-9786208433581
Quantity: Over 20 available
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In. Seller Inventory # ria9786208433581_new
Quantity: Over 20 available
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26404095032
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand. Seller Inventory # 409059303
Quantity: 4 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A new method was established for the determination of extractable flame retardants from textile, foam, leather and plastic test specimens. The flame retardants were extracted with toluene from test specimens using ultrasonic assisted extraction with extraction time of 60 min at 60 ºC. Flame retardants were separated on a DB-XLB column using gas chromatography mass spectrometry (GC-MS) with helium (99.9 %) as carrier gas. One target and two qualifier ions were selected for target analyte under SIM/SCAN mode. Pre-treatment parameters were optimized, including the type of extractant, extraction method and extraction time. Under optimized conditions, recoveries of target compounds ranged from 90 to 100.8 %. Calibration curve working range was 0.25 to 5.0 mg L-1 with regression value 0.996-0.998. Relative standard deviation (RSD) was <15% for test specimens and <10% for pure standards respectively. Limit of detections (LODs) were lower than 0.02 mg L-1 level. The proposed method was successfully used for the determination of actual specimens with concentrations ranging from 1.20 to 18.34 mg L-1. 60 pp. Englisch. Seller Inventory # 9786208433581
Quantity: 2 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND. Seller Inventory # 18404095026
Quantity: 4 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A new method was established for the determination of extractable flame retardants from textile, foam, leather and plastic test specimens. The flame retardants were extracted with toluene from test specimens using ultrasonic assisted extraction with extraction time of 60 min at 60 ºC. Flame retardants were separated on a DB-XLB column using gas chromatography mass spectrometry (GC-MS) with helium (99.9 %) as carrier gas. One target and two qualifier ions were selected for target analyte under SIM/SCAN mode. Pre-treatment parameters were optimized, including the type of extractant, extraction method and extraction time. Under optimized conditions, recoveries of target compounds ranged from 90 to 100.8 %. Calibration curve working range was 0.25 to 5.0 mg L-1 with regression value 0.996-0.998. Relative standard deviation (RSD) wasVDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 60 pp. Englisch. Seller Inventory # 9786208433581
Quantity: 1 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A new method was established for the determination of extractable flame retardants from textile, foam, leather and plastic test specimens. The flame retardants were extracted with toluene from test specimens using ultrasonic assisted extraction with extraction time of 60 min at 60 ºC. Flame retardants were separated on a DB-XLB column using gas chromatography mass spectrometry (GC-MS) with helium (99.9 %) as carrier gas. One target and two qualifier ions were selected for target analyte under SIM/SCAN mode. Pre-treatment parameters were optimized, including the type of extractant, extraction method and extraction time. Under optimized conditions, recoveries of target compounds ranged from 90 to 100.8 %. Calibration curve working range was 0.25 to 5.0 mg L-1 with regression value 0.996-0.998. Relative standard deviation (RSD) was <15% for test specimens and <10% for pure standards respectively. Limit of detections (LODs) were lower than 0.02 mg L-1 level. The proposed method was successfully used for the determination of actual specimens with concentrations ranging from 1.20 to 18.34 mg L-1. Seller Inventory # 9786208433581
Quantity: 2 available