Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 60°C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r² ≥ 0.9995) and recovery rates of 100 ± 15%. LOQs ranged from 0.02 - 0.2 mg L⁻¹, with detected levels between 5.18 - 1798.14 mg L⁻¹. These methods effectively identified controlled substances across various matrices.
"synopsis" may belong to another edition of this title.
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Seller Inventory # I-9786208433895
Quantity: Over 20 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 60°C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r 0.9995) and recovery rates of 100 ± 15%. LOQs ranged from 0.02 - 0.2 mg L , with detected levels between 5.18 - 1798.14 mg L . These methods effectively identified controlled substances across various matrices. 264 pp. Englisch. Seller Inventory # 9786208433895
Quantity: 2 available
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 600C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r2 >= 0.9995) and recovery rates of 100 15%. LOQs ranged from 0.02 - 0.2 mg L1, with detected levels between 5.18 - 1798.14 mg L1. These methods effectively identified controlled substances across various matrices. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Seller Inventory # 9786208433895
Quantity: 1 available
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26404397537
Quantity: 4 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Newly regulated toxicants like flame retardants, phthalates, biocides (MIT, CIT, OIT, Triclosan), ortho-phenylphenols, DMFu, and azo dyes lack certified testing methods, making detection in consumer products difficult. To address this, sensitive and rapid analytical techniques were developed for textiles, foam, leather, and plastics. Samples were extracted using an organic solvent at 60°C for 60 min with sonication, followed by centrifugation and filtration. Toxicants were analyzed using GC/MS with a DB-5MS column and helium gas or UFLC. Extraction conditions were optimized, achieving good linearity (r 0.9995) and recovery rates of 100 ± 15%. LOQs ranged from 0.02 - 0.2 mg L , with detected levels between 5.18 - 1798.14 mg L . These methods effectively identified controlled substances across various matrices. Seller Inventory # 9786208433895
Quantity: 2 available
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand. Seller Inventory # 409805374
Quantity: 4 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND. Seller Inventory # 18404397547
Quantity: 4 available