Applications of Solid Phase Microextraction
Language: English
Published by RSC Publishing Apr 1999, 1999
- Hardcover
- New

Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
AbeBooks seller since August 14, 2006
Condition: New
US$ 172.57
Quantity: 2 available
Add to basketItem description from seller
Neuware - Solid Phase Microextraction (SPME) has been introduced as a modern alternative to current sample preparation technology, and has a wide range of applications. Focusing on quantitative aspects of analysis, Applications of Solid Phase Microextraction aims to describe these applications.In industry, practical uses of SPME can be found in environmental, food, pharmaceutical, clinical and forensic applications, all of which are described in this book. Important scientific applications such as reaction monitoring, characterization of coatings and distributions of analytes in natural multiphase systems are also discussed. Throughout there are descriptions of new technologies, including new coatings and interfaces for analytical instrumentation (SPME/LC and SPME/CE), automation and calibration processes.Written by internationally recognised experts, edited by the scientist involved in the research since its infancy, and encompassing a wide range of applications, this book will be ideal for anyone wishing to explore the feasibility of using SPME technology.…
Seller Inventory # 9780854045259
- Title
- Applications of Solid Phase Microextraction
- Author
- Janusz Pawliszyn
- Publisher
- RSC Publishing Apr 1999
- Publication year
- 1999
- Condition
- Neu
- Binding
- Buch
- Language
- English
- ISBN 10
- 0854045252
- ISBN 13
- 9780854045259
- Item weight
- 1,089 grams
- Dimensions
- 243x165x43 mm
Solid Phase Microextraction (SPME) has been introduced as a modern alternative to current sample preparation technology, and has a wide range of applications. Focusing on quantitative aspects of analysis, Applications of Solid Phase Microextraction aims to describe these applications.
In industry, practical uses of SPME can be found in environmental, food, pharmaceutical, clinical and forensic applications, all of which are described in this book. Important scientific applications such as reaction monitoring, characterization of coatings and distributions of analytes in natural multiphase systems are also discussed. Throughout there are descriptions of new technologies, including new coatings and interfaces for analytical instrumentation (SPME/LC and SPME/CE), automation and calibration processes.
Written by internationally recognised experts, edited by the scientist involved in the research since its infancy, and encompassing a wide range of applications, this book will be ideal for anyone wishing to explore the feasibility of using SPME technology.
"Synopsis" may belong to another edition of this title.
Excerpt. © Reprinted by permission. All rights reserved.
Applications of Solid Phase Microextraction
By Janusz PawliszynThe Royal Society of Chemistry
All rights reserved.
Contents
Glossary, xvii,
Calibration and Quantitation by SPME,
Chapter 1 Quantitative Aspects of SPME Janusz Pawliszyn, 3,
Chapter 2 Quantitation by SPME before Reaching a Partition Equilibrium Jiu Ai, 22,
Coatings and Interfaces,
Chapter 3 SPME Coupled to Capillary Electrophoresis Chen-Wen Whang, 41,
Chapter 4 Selectivity in SPME Shu Li and Stephen G. Weber, 49,
Chapter 5 Properties of Commercial SPME Coatings Venkatachalam Mani, 57,
Chapter 6 Sol-Gel Technology for Thermally Stable Coatings in SPME Abdul Malik and Sau L. Chong, 73,
Chapter 7 Solid versus Liquid Coatings Tadeusz Górecki, 92,
Physicochemical Applications,
Chapter 8 Application of SPME to Study Sorption Phenomena on Dissolved Humic Organic Matter Frank-Dieter Kopinke, Jürgen Pörschmann and Anett Georgi, 111,
Chapter 9 The Use of SPME to Measure Free Concentrations and Phospholipid/Water and Protein/Water Partition Coefficients Wouter H.J. Vaes, Eñaut Urrestarazu Ramos, Karin C.H.M. Legierse and Joop L.M. Hermens, 129,
Chapter 10 Estimation of Hydrophobicity of Organic Compounds Albrecht Paschke and Peter Popp, 140,
Environmental Applications,
Chapter 11 Air Sampling with SPME Perry A. Martos, 159,
Chapter 12 The Application of SPME in Water Analysis Christoph Grote and Karsten Levsen, 169,
Chapter 13 The Application of SPME to Pesticide Residue Analysis Stephen J. Crook, 188,
Chapter 14 Inter-laboratory Validation of SPME for the Quantitative Analysis of Aqueous Samples Torben Nilsson and Tadeusz Górecki, 201,
Chapter 15 SPME for the Determination of Organochlorine Pesticides in Natural Waters Kok Kay Chee, Ming Keong Wong and Hian Kee Lee, 212,
Chapter 16 Determination of Sulfur-containing Compounds in Wastewater Peter Popp, Monika Möder and Imelda McCann, 227,
Chapter 17 Analysis of Creosote and Oil in Aqueous Contaminations by SPME Sys Stybe Johansen, 238,
Chapter 18 Direct Analysis of Solids Using SPME John R. Dean and P. Hancock, 248,
Chapter 19 Analysis of Solid Samples by Hot Water Extraction–SPME Hiroyuki Daimon, 258,
Chapter 20 Field Analysis by SPME Laura Müller, 269,
Chapter 21 Organometallic Speciation by Combining Aqueous Phase Derivatization with SPME–GC–FPD-MS Josep M. Bayona, 284,
Chapter 22 Metal Speciation by SPME–CGC–ICPMS Tom De Smaele, Luc Moens, Richard Dams and Pat Sandra, 296,
Chapter 23 The Application of SPME–LC–MS to the Determination of Contaminants in Complex Environmental Matrices Monika Möder and Peter Popp, 311,
Chapter 24 SPME–HPLC of Environmenta1 Pollutants Anna A. Boyd-Boland, 327,
Chapter 25 Analysis of Industrial Pollutants in Environmental Samples Emilio Benfenati, Laura Müller, L. Perani and P. Pierucci, 333,
Food, Flavour, Fragrance and Pheromone Applications,
Chapter 26 Analysis of Food and Plant Volatiles Adam J. Matich, 349,
Chapter 27 Application of SPME to Measure Volatile Metabolites Produced by Staphylococcus carnosus and Staphylococcus xylosus Régine Talon and M.C. Montel, 364,
Chapter 28 Application of SPME Methods for the Determination of Volatile Wine Aroma Compounds in View of the Varietal Characterization Demetrio De la Calle Garcia and Manfred Reichenbächer, 372,
Chapter 29 Analysis of Vodkas and White Rums by SPME–GC–MS Lay-Keow Ng, 393,
Chapter 30 Analysis of Food Volatiles Using SPME Terry J. Braggins, Casey C. Grimm and Frank R. Visser, 407,
Chapter 31 Analysis of Volatile Contaminants in Foods B. Denis Page, 423,
Chapter 32 Determination of Pesticides in Foods by Automated SPME–GC–MS Ke-Wu Yang, Ralf Eisert, Heather Lord and Janusz Pawliszyn, 435,
Chapter 33 SPME in the Study of Chemical Communication in Social Wasps Gloriano Moneti, G. Pieraccini, M. Sledge and S. Turillazzi, 448,
Pharmaceutical, Clinical and Forensic Applications,
Chapter 34 Propyl Chloroformate Derivatisation and SPME–GC for Screening of Amines in Urine Mette Krogh, Stig Pedersen-Bjergaard and Knut E. Rasmussen, 461,
Chapter 35 Isolation of Drugs and Poisons in Biological Fluids by SPME Takeshi Kumazawa, Xiao-Pen Lee, Keizo Sato and Osamu Suzuki, 470,
Chapter 36 On-fiber Derivatization for Analysis of Steroids by SPME and GC–MS Nicholas H. Snow, 486,
Chapter 37 SPME–Quadrupole Ion Trap Mass Spectrometry for the Determination of Drugs of Abuse in Biological Matrices Brad J. Hall and Jennifer S. Brodbelt, 497,
Chapter 38 Analysis of Drugs in Biological Fluids Using SPME Akira Namera, Mikio Yashiki and Tohru Kojima, 510,
Chapter 39 SPME–Microcolumn LC: Application to Toxicological Drug Analysis Kiyokatsu Jinno, Masahiro Taniguchi, Hirokazu Sawada and Makiko Hayashida, 527,
Chapter 40 Optimization of Drug Analysis by SPME Heather Lord, 540,
Chapter 41 Applications of SPME for the Biomonitoring of Human Exposure to Toxic Substances Maurizio Guidotti and Matteo Vitali, 557,
Chapter 42 Applications of SPME in Criminal Investigations Tsuyoshi Kaneko, 573,
Reaction Monitoring,
Chapter 43 SPME–GC–MS Detection Analysis of Maillard Reaction Products W.M. Coleman, III, 585,
Chapter 44 SPME Investigation of Intermediates Produced during Biodegradation of Contaminated Materials Jalal A. Hawari, 609,
Related Techniques,
Chapter 45 Infrared Spectroscopic Detection for SPME Danese C. Stahl and David C. Tilotta, 625,
Chapter 46 SPME in Near-IR Fiber-optic Evanescent Field Absorption Spectroscopy: A Method for Rapid, Remote In situ Monitoring of Nonpolar Organic Compounds in Water Jochen Bürck, 638,
Subject Index, 654,
CHAPTER 1
Quantitative Aspects of SPME
JANUSZ PAWLISZYN
1 Introduction
The objective of this chapter is to introduce the basic concepts facilitating accurate and precise quantitation using SPME technology. The information presented below is a summary of the comprehensive discussion of the topic covered in the recently published book.
Solid Phase Microextraction (SPME) was introduced as a solvent-free sample preparation technique. The basic principle of this approach is to use a small amount of the extracting phase, usually less than 1 µL. Sample volume can be very large, when the investigated system is sampled directly, for example air in a room or lake water. The extracting phase can be either high molecular weight polymeric liquid, similar in nature to stationary phases in chromatography, or it can be a solid sorbent, typically of a high porosity to increase the surface area available for adsorption.
To date, the most practical geometric configuration of SPME utilizes a small fused silica fibre, usually coated with a polymeric phase. The fibre is mounted for protection in a syringe-like device. The analytes are absorbed, or adsorbed, by the fibre phase (depending on the nature of the coating) until an equilibrium is reached in the system. The amount of an analyte extracted by the coating at equilibrium is determined by the magnitude of the partition coefficient (distribution ratio) of the analyte between the sample matrix and the coating material.
In SPME, analytes typically are not extracted quantitatively from the matrix. However, equilibrium methods are more selective because they take full advantage of the differences in extracting-phase/matrix distribution constants to separate target analytes from interferences. Exhaustive extraction can be achieved in SPME when the distribution constants are large enough. This can be accomplished for most compounds by the application of internally cooled fibre. In exhaustive extraction, selectivity is sacrificed to obtain a quantitative transfer of target analytes into the extracting phase. One advantage of this approach is that, in principle, it does not require calibration, since all the analytes of interest are transferred to the extracting phase. On the other hand, the equilibrium approach usually requires calibration for complex samples. This is usually accomplished by using surrogates, or standard addition technique, to quantify the analytes and to compensate for matrix-to-matrix variations and their effect on distribution constants.
Since equilibrium rather than exhaustive extraction occurs in the microextraction methods, SPME is ideal for field monitoring. It is unnecessary to measure the volume of the extracted sample, and therefore the SPME device can be exposed directly to the investigated system for quantitation of target analytes. In addition, extracted analytes are introduced to analytical instrument simply by placing the fibre in the desorbtion unit (Figures lb and lc). This convenient, solvent free process facilitate sharp injection bands and rapid separations. These features of SPME result in integration of the first steps in analytical process: sampling, sample preparation and introduction of extracted mixture to an analytical instrument.
The equilibrium nature of the technique also facilitates speciation in natural systems since the presence of a minute fibre, which removes small amounts of target analytes, is not likely to disturb the system. Because of the small size, coated fibres can be used to extract analytes from very small samples. For example, SPME has been used to probe for substances emitted by a single flower bulb during its lifespan.
Figure 1a illustrates the commercial SPME device, manufactured by Supelco, Inc. (Bellefonte, PA). The fibre, glued into a piece of stainless steel tubing, is mounted in a special holder. The holder is equipped with an adjustable depth gauge, which makes it possible to control repeatably how far the needle of the device is allowed to penetrate the sample container (if any) or the injector. This is important, as the fibre can be easily broken when it hits an obstacle. The movement of the plunger is limited by a small screw moving in the z-shaped slot of the device. For protection during storage or septum piercing, the fibre is withdrawn into the needle of the device, with the screw in the uppermost position. During extraction or desorption, the fibre is exposed by depressing the plunger, which can be locked in the lowered (middle) position by turning it clockwise (the position depicted in Figure la). The plunger is moved to its lowermost position only for replacement of the fibre assembly. Each type of fibre has a hub of a different colour. The hub-viewing window enables a quick check of the type of fibre mounted in the device.
If the sample is placed in a vial, the septum of the vial is first pierced with the needle (with the fibre in the retracted position), and the plunger is lowered, which exposes the fibre to the sample. The analytes are allowed to partition into the coating for a predetermined time, and the fibre is then retracted back into the needle. The device is next transferred to the analytical instrument of choice. When gas chromatography (GC) is used for analyte separation and quantitation, the fibre is inserted into a hot injector, where thermal desorption of the trapped analytes takes place (Figure 1c). The process can be automated by using an appropriately modified syringe autosampler. For HPLC applications, a simple interface mounted in a place of the injection loop can be used to re-extract analytes into the desorption solvent (Figure 1b).
The SPME device is capable for both spot and time-averaged sampling. As described above, for spot sampling, the fibre is exposed to a sample matrix until the partitioning equilibrium is reached between the sample matrix and the coating material. In a time-average approach, on the other hand, the fibre remains in the needle during the exposure of the SPME device to the sample. The coating works as a trap for analytes that diffuse into the needle, resulting in an accumulated mass of analyte proportional to an integral of concentration over time (see equation 10).
SPME sampling can be performed in three basic modes: direct extraction, headspace extraction, and extraction with membrane protection. Figure 2 illustrates the differences between these modes. In direct extraction mode (Figure 2a), the coated fibre is inserted into the sample and the analytes are transported directly from the sample matrix to the extracting phase. To facilitate rapid extraction, some level of agitation is required to transport the analytes from the bulk of the sample to the vicinity of the fibre. For gaseous samples, the natural flow of air (e.g. convection) is frequently sufficient to facilitate rapid equilibration, but for aqueous matrices, more efficient agitation techniques, such as fast sample flow, rapid fibre or vial movement, stirring or sonication are required to reduce the effect of a 'depletion zone' produced close to the fibre as a result of slow diffusional transport of analyte through the stationary layer of liquid matrix surrounding the fibre.
In the headspace mode (Figure 2b), the analytes are extracted from the gas phase equilibrated with the sample. The primary reason for this modification is to protect the fibre from adverse effects caused by non-volatile, high molecular weight substances present in the sample matrix (e.g. humic acids or proteins). The headspace mode also allows matrix modifications, including pH adjustment, without affecting the fibre. In a system consisting of a liquid sample and its headspace, the amount of an analyte extracted by the fibre coating does not depend on the location of the fibre in the liquid phase or in the gas phase, therefore the sensitivity of headspace sampling is the same as the sensitivity of direct sampling as long as the volumes of the two phases are the same in both sampling modes. Even when no headspace is used in direct extraction, a significant sensitivity difference between direct and headspace sampling can occur only for very volatile analytes. However, the choice of sampling mode has a very significant impact on the extraction kinetics. When the fibre is in the headspace, the analytes are removed from the headspace first, followed by indirect extraction from the matrix. Therefore, volatile analytes are extracted faster than semivolatiles. Temperature has a significant effect on the kinetics of the process, since it determines the vapour pressure of analytes. In general, the equilibration times for volatile compounds are shorter for headspace SPME extraction than for direct extraction under similar agitation conditions, because of the following three reasons: a substantial portion of the analytes is present in the headspace prior to the beginning of the extraction process, there is typically large interface between sample matrix and headspace, and the diffusion coefficients in the gas phase are typically higher by four orders of magnitude than in liquids. As the concentration of semivolatile compounds in the gaseous phase at room temperature is small, headspace extraction rates for those compounds are substantially lower. They can be improved by using very efficient agitation or by increasing the extraction temperature.
In the third mode (SPME extraction with membrane protection, Figure 2c), the fibre is separated from the sample with a selective membrane, which lets the analytes through while blocking the intereferences. The main purpose for the use of the membrane barrier is to protect the fibre against adverse effects caused by high molecular weight compounds when very dirty samples are analysed. While extraction from headspace serves the same purpose, membrane protection enables the analysis of less volatile compounds. The extraction process is substantially slower than direct extraction because the analytes need to diffuse through the membrane before they can reach the coating. The use of thin membranes and an increase in the extraction temperature result in shorter extraction times.
2 Theoretical Aspects of Solid Phase Microextraction Optimization and Calibration
Thermodynamics
Solid phase microextraction is a multiphase equilibration process. Frequently, the extraction system is complex, as in a sample consisting of an aqueous phase with suspended solid particles having various adsorption interactions with analytes, plus a gaseous headspace. In some cases specific factors have to be considered, such as analyte losses by biodegradation or adsorption on the walls of the sampling vessel. In the discussion below we will only consider three phases: the fibre coating, the gas phase or headspace, and a homogeneous matrix such as pure water or air. During extraction, analytes migrate between all three phases until equilibrium is reached.
The mass of an analyte extracted by the polymeric coating is related to the overall equilibrium of the analyte in the three-phase system. Since the total mass of an analyte should remain constant during the extraction, we have:
[MATHEMATICAL EXPRESSION NOT REPRODUCIBLE IN ASCII] (1)
where C0 is the initial concentration of the analyte in the matrix; C∞f, C∞h, and C∞s are the equilibrium concentrations of the analyte in the coating, the headspace, and the matrix, respectively; Vf, Vh, and Vs are the volumes of the coating, the headspace, and the matrix, respectively. If we define the coating/gas distribution constant as Kfh = C∞ f/C∞h, and the gas/sample matrix distribution constant as Khs = C∞h/C∞s, the mass of the analyte absorbed by the coating, n = C∞fVf can be expressed as:
n = KfhKhsVfC0Vs/ KfhKhsVf + KhsVh + Vs (2)
Also
Kfs = KfhKhs = KfgKgs (3)
since the fibre/headspace distribution constant, Kfh can be approximated by the fibre/gas distribution constant Kfg, and the headspace/sample distribution constant, Khs, by the gas/sample distribution constant, Kgs, if the effect of moisture in the gaseous headspace can be neglected. Thus, equation 2 can be rewritten as:
n = KfsVfC0Vs/ KfsVf + KhsVh + Vs (4)
(Continues...)
Excerpted from Applications of Solid Phase Microextraction by Janusz Pawliszyn. Copyright © 1999 The Royal Society of Chemistry. Excerpted by permission of The Royal Society of Chemistry.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.
"About the title" may belong to another edition of this title.
Shipping rates from Germany to U.S.A.
| Item | 7 to 10 business days | 5 to 7 business days |
|---|---|---|
| First item | US$ 47.90 | US$ 65.26 |
Payment methods
- Bank Wire Transfer
- Check
- Paypal
Store description
Das Unternehmen AHA-BUCH GmbH: Seit der Gründung von AHA-BUCH im Juli 2005 ist unser Hauptziel, zufriedenen Kunden so schnell und so preisgünstig wie möglich ihren Bücherwunsch zu erfüllen. Unsere Firma beschäftigt 16 Mitarbeiter, die nur ein Ziel kennen: den Kunden und seine Wünsche! Auf über 3700 m2 Fläche haben wir über 100.000 Bücher, Modernes Antiquariat und Spiele auf Lager.
Specialty
Kinderbücher & Kinderhör Casetten, German Books, Software, Natur & Tiere, Ratgeber, Sachbücher, Englische Bücher, Medizin & Gesundheit, Universität & StudiumSeller's business information
AHA-BUCH GmbH
Garlebsen 48
Einbeck, Germany 37574
Terms of sale
General Terms and Conditions and Customer Information / Privacy Policy
I. General Terms and Conditions
§ 1 Basic provisions
(1) The following terms and conditions apply to all contracts that you conclude with us as a provider (AHA-BUCH GmbH) via the Internet platforms AbeBooks and/or ZVAB. Unless otherwise agreed, the inclusion of any of your own terms and conditions used by you will be objected to
(2) A consumer within the meaning of the following regulations is any natural person who concludes a legal transaction for purposes that can predominantly be attributed neither to their commercial nor their independent professional activity. An entrepreneur is any natural or legal person or a partnership with legal capacity who, when concluding a legal transaction, acts in the exercise of his independent professional or commercial activity.
§ 2 Conclusion of the contract
(1) The object of the contract is the sale of goods.
(2) If an article is listed by us at AbeBooks or ZVAB, the activation of the offer page at AbeBooks or ZVAB constitutes the binding offer to conclude a contract under the conditions contained in the article page.
(3) The contract is concluded via the online shopping cart system as follows:
The goods intended for purchase are stored in the "shopping cart". Via the corresponding button in the navigation bar you can call up the "shopping cart" and make changes there at any time.
After calling up the "Checkout" page and entering the personal data as well as the payment and shipping conditions, all order data will be displayed again on the order overview page.
Before sending the order, you have the option of checking all information again, changing it (also via the "back" function of the Internet browser) or cancelling the purchase.
By submitting the order via the "Buy now" button, you declare the acceptance of the offer in a legally binding manner, whereby the contract is concluded.
(4) The processing of the order and transmission of all information required in connection with the conclusion of the contract is partly automated by e-mail. You must therefore ensure that the e-mail address you have stored with us is correct, that the receipt of the e-mails is technically ensured and, in particular, that spam filters do not prevent it.
§ 3 Right of retention, retention of title
(1) You can only exercise a right of retention if it concerns claims from the same contractual relationship.
(2) The goods remain our property until full payment of the purchase price.
§ 4 Warranty
(1) The statutory warranty rights exist.
(2) In the case of used goods, the warranty period is one year from delivery of the item, deviating from the statutory regulation. The shortening of the deadline does not apply:
- culpably caused damages attributable to us from injury to life, limb or health and in the case of other damages caused intentionally or through gross negligence;
- insofar as we have fraudulently concealed the defect or have assumed a guarantee for the quality of the item.
(3) As a consumer, you are requested to check the item immediately upon delivery for completeness, obvious defects and transport damage and to inform us and the freight forwarder of any complaints as soon as possible. If you do not comply with this, this will have no effect on your statutory warranty claims.
§ 5 Choice of law, place of performance, place of jurisdiction
(1) German law shall apply. In the case of consumers, this choice of law shall only apply insofar as this does not withdraw the protection afforded by mandatory provisions of the law of the state of the consumer's habitual residence (principle of favourability).
(2) The place of performance for all services arising from the existing business relationships with us as well as the place of jurisdiction is our registered office, insofar as you are not a consumer, but a merchant, a legal entity under public law or a special fund under public law. The same applies if you do not have a general place of jurisdiction in Germany or the EU or if the domicile or habitual residence is not known at the time the action is brought. The right to appeal to the court at another statutory place of jurisdiction remains unaffected by this.
(3) The provisions of the UN Convention on Contracts for the International Sale of Goods shall expressly not apply.
II. Customer Information
- Identity of the Seller
AHA-BUCH GmbH
Garlebsen 48
D-37574 Einbeck
Germany
Telephone: 055639996039
E-mail: abebooks@aha-buch.de.
Alternative dispute resolution:
The European Commission provides a platform for out-of-court online dispute resolution (ODR platform), which can be accessed under https://ec.europa.eu/odr.
- Information on the conclusion of the contract
The technical steps for the conclusion of the contract, the conclusion of the contract itself and the correction options are carried out in accordance with the provisions "Conclusion of the contract" of our General Terms and Conditions (Part I.).
- Contract language, contract text storage
3.1. The contract language is german.
3.2. The complete text of the contract will not be stored by us. Before sending the order, the contract data can be printed out or electronically saved via the print function of the browser. After receipt of the order by us, the order data, the legally prescribed information for distance contracts and the General Terms and Conditions will be sent to you again by e-mail.
- Essential characteristics of the goods or services
The essential characteristics of the goods and/or services can be found in the respective offer.
- Prices and terms of payment
5.1. The prices stated in the respective offers as well as the shipping costs represent total prices. They include all price components including all applicable taxes.
5.2. The shipping costs incurred are not included in the purchase price. They can be called up via a correspondingly designated button on our website or in the respective offer, are shown separately in the course of the ordering process and are to be borne by you in addition, unless free shipping has been promised.
5.3. If the delivery is made to countries outside the European Union, we may incur additional costs for which we are not responsible, such as.B customs duties, taxes or money transfer fees (transfer or exchange rate fees of the credit institutions), which are to be borne by you. Any costs incurred for the transfer of money shall also be borne by you in cases where the delivery is made to an EU member state, but the payment was initiated outside the European Union.
5.4. The payment methods available to you are indicated under a corresponding button on our website or in the respective offer.
5.5. Unless otherwise stated for the individual payment methods, the payment claims from the concluded contract are due for payment immediately.
- Terms of delivery
6.1. The terms of delivery, the delivery date and, if applicable, existing delivery restrictions can be found under a correspondingly designated button on our website or in the respective offer.
Insofar as no other deadline is specified in the respective offer or under the correspondingly designated button, the delivery of the goods will take place within 3-5 days after conclusion of the contract (in the case of agreed advance payment, however, only after the time of your payment instruction).
6.2. Insofar as you are a consumer, it is regulated by law that the risk of accidental loss and accidental deterioration of the sold item during dispatch shall only pass to you upon handover of the goods, regardless of whether the shipment is insured or uninsured. This does not apply if you have independently commissioned a transport company not named by the entrepreneur or a person otherwise designated to carry out the shipment.
- Statutory liability for defects
Liability for defects is governed by the "Warranty" provision in our General Terms and Conditions (Part I).
last update: 01/06/2022
Privacy policy
Unless otherwise stated below, the provision of your personal data is neither required by law or contract, nor is it necessary for the conclusion of a contract. You are not obliged to provide the data. Failure to provide this will have no consequences. This only applies if no other information is provided in the subsequent processing operations.
Collection, processing and disclosure of personal data when placing orders
When ordering, we collect and process your personal data only to the extent necessary to fulfil and process your order and to process your enquiries. The provision of the data is necessary for the conclusion of the contract. Failure to provide this provision means that no contract can be concluded. The processing takes place on the basis of Art. 6 para. 1 lit.b GDPR and is necessary for the performance of a contract with you.
Your data will be passed on, for example, to the shipping companies and dropshipping providers selected by you, payment service providers, service providers for order processing and IT service providers.
In all cases, we strictly observe the legal requirements. The scope of data transmission is limited to a minimum.
Duration of storage
After completion of the contract, the data will first be stored for the duration of the warranty period, then taking into account legal, in particular tax and commercial retention periods and then deleted after expiry of the period, unless you have consented to further processing and use.
Rights of the data subject
If the legal requirements are met, you have the following rights under Articles 15 to 20 GDPR: Right to information, to correction, to erasure, to restriction of processing, to data portability.
In addition, pursuant to Article 21 (1) GDPR, you have the right to object to processing based on Article 6 (1) f GDPR and to processing for direct marketing purposes.
Contact us on request. The contact details can be found in our imprint.
Right to lodge a complaint with the supervisory authority
In accordance with Article 77 GDPR, you have the right to complain to the supervisory authority if you believe that the processing of your personal data is not lawful.
Right to object
If the personal data processing listed here is based on our legitimate interest pursuant to Art. 6 para. 1 lit. f GDPR, you have the right to object to this processing at any time with effect for the future for reasons arising from your particular situation.
Shipping terms
We ship your order after we received them
for articles on hand latest 24 hours,
for articles with overnight supply latest 48 hours.
In case we need to order an article from our supplier our dispatch time depends on the reception date of the articles, but the articles will be shipped on the same day.
Our goal is to send the ordered articles in the fastest, but also most efficient and secure way to our customers.