Implantable Pressure Sensor Encapsulation for Ventricular Assist Device Control
Language: English
Published by Hartung & Gorre, 2024
- Softcover
- New

Seller: California Books, Miami, FL, U.S.A.California Books
5-star seller
AbeBooks seller since October 27, 2023
Softcover
Condition: New
US$ 71.00
Free Shipping
Ships within U.S.A.
Quantity: Over 20 available
Add to basketFree 30-day returns
Seller Inventory # I-9783866288348
- Title
- Implantable Pressure Sensor Encapsulation for Ventricular Assist Device Control
- Author
- Dupuch, Matthias Alexander
- Publisher
- Hartung & Gorre
- Publication year
- 2024
- Condition
- New
- Binding
- Soft cover
- Language
- English
- ISBN 10
- 3866288344
- ISBN 13
- 9783866288348
Autonomous feedback controlled ventricular assists device (VAD) operation promises a plethora of benefits such as increased patient safety, comfort, and reduced healthcare costs. Current generation VADs operate at static pump speeds due to the lack of available biocompatible, long-term stable pressure sensor systems. In this thesis, a pressure sensor encapsulation was developed and integrated in an inflow cannula for a VAD and in an implantable testing platform for animal trials. The encapsulation uses a media separating diaphragm embedded in a Parylene C coating. The approach is expanded to enable optimized diaphragm shapes, which allow significantly better control over the final device characteristics, especially the temperature cross sensitivity. Furthermore, a production processes was developed to minimize assembly induced internal overpressure. The produced capsules showed excellent pressure transmission of more than 99.7 % and a temperature cross sensitivity of less than 266 Pa from 35 °C to 42 °C for most capsules. However, a large temperature cross sensitivity was observed from room to body temperature in some capsules, adding relevant drift of 750 Pa (75 % quartile) after 42 days to the measurement. The observed drift is related to the viscoelastic nature of the Parylene C diaphragm and the capsule-to-capsule variation is attributed to production process variations, which can be further optimized. Systematic errors in the pressure transmission, temperature cross sensitivity (TCS), and drift were extracted and correction approaches for each were developed. This enabled the reduction of the pressure transmission error by 50 % by linear correction. A differential measurement approach reduced the temperature cross sensitivity to less than 70 Pa from 35 °C to 42 °C and drastically reduced the temperature induced drift to 300 Pa (75 % quartile) after a jump from room to body temperature. Half of all sensors even remained within a +- 100 Pa window in the same tim
"Synopsis" may belong to another edition of this title.
California Books
Miami, FL, U.S.A.
5-star seller
AbeBooks seller since October 27, 2023
Shipping rates within U.S.A.
| Item | 3 to 7 business days | 2 to 5 business days |
|---|---|---|
| First item | US$ 0.00 | US$ 12.00 |
Payment methods
Store description
We have 20 years experience selling books worldwide! Friendly customer support. Your satisfaction guaranteed!
Specialty
All authorized categoriesSeller's business information
Miramar International Services LLC
FL, U.S.A.
Terms of sale
www.californiabooks.com
Shipping terms
www.californiabooks.com