Introduction to Megavoltage X-Ray Dose Computation Algorithms (Hardcover)
Language: English
Published by Taylor & Francis Ltd, London, 2019
Series: Book 57 of 99 - Series in Medical Physics and Biomedical Engineering
- Hardcover
- New

Seller: AussieBookSeller, Truganina, VIC, AustraliaAussieBookSeller
AbeBooks seller since June 22, 2007
Condition: New
US$ 552.70
Quantity: 1 available
Add to basketItem description from seller
Hardcover. Read an exclusive interview with Dr. Jerry Battista here.A critical element of radiation treatment planning for cancer is the accurate prediction and delivery of a tailored radiation dose distribution inside the patient. Megavoltage x-ray beams are aimed at the tumour, while collateral damage to nearby healthy tissue and organs is minimized. The key to optimal treatment therefore lies in adopting a trustworthy three-dimensional (3D) dose computation algorithm, which simulates the passage of both primary and secondary radiation throughout the exposed tissue.Edited by an award-winning university educator and pioneer in the field of voxel-based radiation dose computation, this book explores the physics and mathematics that underlie algorithms encountered in contemporary radiation oncology. It is an invaluable reference for clinical physicists who commission, develop, or test treatment planning software. This book also covers a core topic in the syllabus for educating graduate students and residents entering the field of clinical physics. This book starts with a historical perspective gradually building up to the three most important algorithms used for todays clinical applications. These algorithms can solve the same general radiation transport problem from three vantages: firstly, applying convolution-superposition principles (i.e. Greens method); secondly, the stochastic simulation of radiation particle interactions with tissue atoms (i.e. the Monte Carlo method); and thirdly, the deterministic solution of the fundamental equations for radiation fields of x-rays and their secondary particles (i.e. the Boltzmann method). It contains clear, original illustrations of key concepts and quantities thoughout, supplemented by metaphors and analogies to facilitate comprehension and retention of knowledge.Features:Edited by an authority in the field, enhanced with chapter contributions from physicists with clinical experience in the fields of computational dosimetry and dose optimizationContains examples of test phantom results and clinical cases, illustrating pitfalls to avoid in clinical applications to radiation oncologyIntroduces four-dimensional (4D) dose computation, on-line dose reconstruction, and dose accumulation that accounts for tissue displacements and motion throughout a course of radiation therapy This book explores the physics and mathematics that underlie the dose computation algorithms used in modern radiation oncology. It is an invaluable reference for clinical practitioners and researchers who wish to utilise the software, in addition to graduate students and residents. Shipping may be from our Sydney, NSW warehouse or from our UK or US warehouse, depending on stock availability.…
Seller Inventory # 9781138056848
- Title
- Introduction to Megavoltage X-Ray Dose Computation Algorithms (Hardcover)
- Author
- Jerry Battista
- Publisher
- Taylor & Francis Ltd, London
- Publication year
- 2019
- Condition
- new
- Binding
- Hardcover
- Language
- English
- ISBN 10
- 1138056847
- ISBN 13
- 9781138056848
- Series
- Book 57 of 99: Series in Medical Physics and Biomedical Engineering
Read an exclusive interview with Dr. Jerry Battista here.
A critical element of radiation treatment planning for cancer is the accurate prediction and delivery of a tailored radiation dose distribution inside the patient. Megavoltage x-ray beams are aimed at the tumour, while collateral damage to nearby healthy tissue and organs is minimized. The key to optimal treatment therefore lies in adopting a trustworthy three-dimensional (3D) dose computation algorithm, which simulates the passage of both primary and secondary radiation throughout the exposed tissue.
Edited by an award-winning university educator and pioneer in the field of voxel-based radiation dose computation, this book explores the physics and mathematics that underlie algorithms encountered in contemporary radiation oncology. It is an invaluable reference for clinical physicists who commission, develop, or test treatment planning software. This book also covers a core topic in the syllabus for educating graduate students and residents entering the field of clinical physics.
This book starts with a historical perspective gradually building up to the three most important algorithms used for today’s clinical applications. These algorithms can solve the same general radiation transport problem from three vantages: firstly, applying convolution-superposition principles (i.e. Green’s method); secondly, the stochastic simulation of radiation particle interactions with tissue atoms (i.e. the Monte Carlo method); and thirdly, the deterministic solution of the fundamental equations for radiation fields of x-rays and their secondary particles (i.e. the Boltzmann method). It contains clear, original illustrations of key concepts and quantities thoughout, supplemented by metaphors and analogies to facilitate comprehension and retention of knowledge.
Features:
- Edited by an authority in the field, enhanced with chapter contributions from physicists with clinical experience in the fields of computational dosimetry and dose optimization
- Contains examples of test phantom results and clinical cases, illustrating pitfalls to avoid in clinical applications to radiation oncology
- Introduces four-dimensional (4D) dose computation, on-line dose reconstruction, and dose accumulation that accounts for tissue displacements and motion throughout a course of radiation therapy
"Synopsis" may belong to another edition of this title.
About the Author
Dr. Jerry Battista completed his Ph.D. degree at the University of Toronto in 1977 (Compton Tomography). As a post-doctoral resident in medical physics he then gained clinical physics experience at the Princess Margaret Hospital, under the guidance of Dr.“Jack” Cunningham – a pioneer in computerized dose calculations. Jerry moved to the Cross Cancer Institute and University of Alberta in 1979. His team developed one of the first “3D” treatment planning systems and introduced a new breed of ‘convolution/superposition’ algorithms used for planning radiotherapy of cancer patients. Current research interests include 3D dose measurements in gels using optical CT scans, and adaptive dose re-optimization for image-guided radiotherapy. He has published over 120 peer-reviewed articles.
Jerry is a Fellow of the Canadian College of Physicists in Medicine (FCCPM), Canadian Organization of Medical Physics (FCOMP) and American Association of Physicists in Medicine (FAAPM). Since 1988, Dr. Battista has been driving Physics Research at the London Regional Cancer Program, in London, Ontario, Canada. He is Professor of Medical Biophysics at Western University, with cross-appointments to the Departments of Oncology, Physics, Diagnostic Imaging and Nuclear Medicine, and the Biomedical Engineering Program.
Jerry is an award-winning teacher and he is nationally known for his clear presentations. His enthusiastic style and vivid analogies bring physics concepts to a wide range of audiences with diverse backgrounds, including clinicians, students, and the general public. He has received the university’s top honour for teaching excellence. Dr. Battista has mentored many graduate students, who collectively have received over 20 awards from Canadian, and international, organizations, for excellence in publications or presentations.
Jerry was the recipient of the 2017 Gold Medal Award from the Canadian Organization of Medical Physicists (COMP).
"About the title" may belong to another edition of this title.
AussieBookSeller
Truganina, VIC, Australia
AbeBooks seller since June 22, 2007
Shipping rates from Australia to U.S.A.
| Item | 25 to 45 business days | 8 to 14 business days |
|---|---|---|
| First item | US$ 37.00 | US$ 44.00 |
Payment methods
Seller's business information
The Nile Group Pty Ltd
42 Apex Drive
Truganina, VIC Australia 3029
Terms of sale
We guarantee the condition of every book as it's described on the Abebooks web sites. If you're dissatisfied with your purchase (Incorrect Book/Not as Described/Damaged) or if the order hasn't arrived, you're eligible for a refund within 30 days of the estimated delivery date. If you've changed your mind about a book that you've ordered, please use the Ask bookseller a question link to contact us and we'll respond within 2 business days.
Shipping terms
Please note that titles are dispatched from our UK and NZ warehouse. Delivery times specified in shipping terms. Orders ship within 2 business days. Delivery to your door then takes 8-15 days.