Introduction to Power System Protection
Language: English
Published by Blurb, US, 2026
- Softcover
- New

Seller: Rarewaves.com USA, London, London, United KingdomRarewaves.com USA
5-star seller
AbeBooks seller since June 11, 2025
Softcover
Condition: New
US$ 30.68
Free Shipping
Ships from United Kingdom to U.S.A.
Quantity: Over 20 available
Add to basketFree 30-day returns
Seller Inventory # LU-9798211894259
- Title
- Introduction to Power System Protection
- Author
- Hidaia Mahmood Alassouli
- Publisher
- Blurb, US
- Publication year
- 2026
- Condition
- New
- Binding
- Paperback
- Language
- English
- ISBN 13
- 9798211894259
- Item weight
- 318 grams
Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. System-protection components have the following design criteria: - Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. - Selectivity: Avoid unnecessary, false trips. - Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. - Economy: Provide maximum protection at minimum cost. - Simplicity: Minimize protection equipment and circuitry. Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.
"Synopsis" may belong to another edition of this title.
Rarewaves.com USA
London, London, United Kingdom
5-star seller
AbeBooks seller since June 11, 2025
Shipping rates from United Kingdom to U.S.A.
| Item | 9 to 14 business days | 9 to 14 business days |
|---|---|---|
| First item | US$ 0.00 | US$ 0.00 |
Payment methods
Seller's business information
RAREWAVES.COM LIMITED
Elsley Court, 20-22 Great Titchfield Street
London, United Kingdom W1W 8BE
Shipping terms
Please note that we do not offer Priority shipping to any country.
We currently do not ship to the below countries:
Russia
Belarus
Ukraine
Please do not attempt to place orders with any of these countries as a ship to address - they will be cancelled.