Microtas 2004 : Volume 2
Language: English
Published by Royal Society Of Chemistry Sep 2004, 2004
- Hardcover
- New

Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
AbeBooks seller since August 14, 2006
Condition: New
US$ 207.07
Quantity: 2 available
Add to basketItem description from seller
Neuware - This volume is the second in a two volume set, a valuable reference collection to all working in this field.
Seller Inventory # 9780854048960
- Title
- Microtas 2004 : Volume 2
- Author
- J P Kutter
- Publisher
- Royal Society Of Chemistry Sep 2004
- Publication year
- 2004
- Condition
- Neu
- Binding
- Buch
- Language
- English
- ISBN 10
- 0854048960
- ISBN 13
- 9780854048960
- Item weight
- 1,240 grams
- Dimensions
- 241x160x41 mm
The Eighth International Conference on Miniaturized Systems in Chemistry and Life Science - MicroTas 2004 - is an annual meeting focusing on the research, development and application of miniaturized technologies and methodologies in chemistry and life science. The conference is celebrating its tenth anniversary after the first workshop at the University of Twente, The Netherlands in 1994. This research field is rapidly developing and changing towards a domain where core competence areas such as microfluidics, micro- and nanotechnology, materials science, chemistry, biology, and medicine are melting together to a truly interdisciplinary meeting place. This volume is the second in a two volume set, a valuable reference collection to all working in this field.
"Synopsis" may belong to another edition of this title.
Excerpt. © Reprinted by permission. All rights reserved.
Micro Total Analysis Systems 2004 Volume 2
Proceedings of µTAS 2004 8th International Conference on Miniaturized Systems for Chemistry and Life Sciences
By Thomas Laurell, Johan Nilsson, Klavs Jensen, D. Jed Harrison, Jörg P. KutterThe Royal Society of Chemistry
All rights reserved.
Contents
Volume 2,
Day 2 - Tuesday, September 28,2004,
Tuesday Poster Session - MEMS Technology I,
Tuesday Poster Session - Materials,
Tuesday Session A - Pumping,
Tuesday Session B - Protein Crystallization,
Day 3 - Wednesday, September 29,2004,
Plenary V,
Wednesday Session A - Cell Lysis,
Wednesday Session B - Separation,
Wednesday Session A - Gene Analysis,
Wednesday Session B - NMR,
Wednesday Plenary VI,
Wednesday Poster Session - Applications III,
Wednesday Poster Session - MEMS Technology II,
Wednesday Session A - Two-Phase Systems,
Wednesday Session B - Coupling to MS,
Day 4 - Thursday, September 30,2004,
Thursday Session A - Cell Culture I1,
Thursday Session B - Analysis,
Thursday Session A - Microfluidics, Others,
Thursday Session B - On-Chip Monitoring,
AUTHOR INDEX, 587,
KEY WORD INDEX, 596,
CHAPTER 1
FABRICATING A THREE-DIMENSIONAL CHANNEL FOR MICRO-FLUIDIC DEVICES BY LASER ABLATION
Yoshikazu Yoshida, Tsutomu Neichi, Retsu Tahara, Jun Yamada, Hiroyuki Yamada and Nobuyuki Terada
Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 Yamanashi Pref. Industrial Technology Center, 2094 Kofu, Yamanashi 400-0055, Japan University of Yamanashi, 1110 Tamaho, Nakakoma, Yamanashi 409-3898, Japan
Abstract
This paper describes the fabrication in resin of micro-channels for micro-fluidic devices such as the µTAS (Micro Total Analysis System) by UV laser ablation process. A number of heat-hardening resin-films are layered on a soda glass. A laser fabricates a part of the channel on each film for every lamination. Then three-dimensional (3-D) confluence channels are fabricated. The fabricated channels are 45-180 µm in depth and 50-300 µm in width. The through holes are made in the laminate film with a laser. An inlet pipe for a micro-pump is inserted into the hole.
Keywords: µTAS, UV laser, lamination, resin-films, blood
1. Introduction
Recently, in various fields the necessity for small and highly sensitive micro-fluidic analysis systems has increase. Therefore a µTAS has received considerable attention. The µTAS is the size of a card, and has miniaturized channels, detectors, and other elements for fluidic analysis. The advantages of this system are the reduced need of fluidic samples, reagents, and hours of detection. The size of the fluidic analysis elements on the µTAS is a few score micrometers. There are many fabrication methods of micro-channels through semiconductor technology, plastic molding, and laser fabrication of resins. The laser fabrication method has recently been receiving much attention. The advantages of this method are: one stroke fabrication of grooves for channels, an easy change of groove patterns, and 3-D fabrication to allow grooves with slopes and differences in levels. We have been proposing the method which uses silicon or quartz as the substrate part of µTAS, build the micro working parts and electrode in advance onto the substrate, then create the flow path and cistern on the resin part formed on the substrate, An ultraviolet pulse laser was used to form such items as the flow path. A number of heat-hardening resin-films were layered on a soda glass. A laser fabricated a part of the channel on each film for every lamination, and then a 3-D micro-channel structure was fabricated. Two types of flow path, a plane and an overpass, are fabricated.
2. Experiment equipment
The substrate is soda glass laminated by heat-hardening resin-film. This film is made of two films, one of 25µm thick polyimide and the other 20µm thick epoxy. Channels are fabricated by a pulse Nd:YAG laser system (Brilliant; Quantel) and a KrF excimer laser system (LPX220; Lambda Physik, AG). For the experiment condition, the YAG has a wavelength of 266nm, pulse energy of 3.1mJ, pulse width of 4.3nsec, and repetition rate of 10Hz. The laser beam is fixed, and the substrate is moved in the XY stage. This stage has a positional bi-directional repeatability of [+ or -] 5pm. The excimer has a wavelength of 248nm, output energy of 8-80W, maximum pulse energy of 450mJ, pulse width of 10-20nsec, and repetition rate of 25-200Hz. A mask is used to shape the laser beam into a square shape to allow fabrication with smooth wall surfaces at low overlap rate conditions. The laser beam is focused to the width of a groove.
3. Results and discussion
3.1 Three-pronged channel
Combining of laminar flows in a micro-channel makes possible the study of blood cell analysis. Figure 1 shows an optical photomicrograph of three-pronged grooves without cover film fabricated by the excimer laser. Channels have a width of 50pm and a depth of 45µm in three-pronged parts, and a width of 150µm in a confluence part. Blood is injected at a low flow rate between two rapidly flowing streams of physiological salt solution. The width of the stream of blood can be controlled by the height difference between a blood reservoir and solution reservoir, that is potential energy. The width narrows as it climbs to the speed of the neighboring streams. The width decreases with the increasing height difference. The cells velocity increases with the increasing height difference. In this experiment, the channel substrate is placed horizontally on a microscope stand, and the reservoir made from a connector between a syringe and a needle is connected to the channel inlet with Silicon tube. This tube has an external diameter of 1mm and an inside diameter of 0.3mm. Figure 2 shows a focused picture of blood when the blood reservoir is 200mm high and the solution is 400mm high from the channel. The cells velocity is almost 15.5mm/s. It is almost 9mm/s when the height difference is nearly zero. As shown in Fig.2 (b), blood cells can be measured individually.
3.2 Three-dimensional channels
Figure 3 shows the optical photomicrograph of a channel made on the second film by the YAG laser. The laser scanning distance is 150µm. The second film is peeled off from the first one by the scanning. The film placed between the scanning is removed from the substrate. The space caused by removal of the film is used as a channel space. The film peelings on the channel side are removed with the following laminating process.
Figure 4 shows the production process of the steric mixture flow path used to branch. There are 3-D pattern diagrams and optical photomicrographs each time a lamination is done. First, the channel element of the first layer is made for the film on the glass by the laser (Fig.4 (a)). After that, the second film is laminated on the first one, and the channel element is made on the film (b). These processes are iterated several times, and the 3-D confluence channel is fabricated. The channel is closed because the groove is treated with laminate processing, and liquid can't enter into the groove. Therefore it is necessary to make a perforated hole in the flow path to insert liquid inside, and connect the tube. The diameter of the hole is 150pm, and formed on the laminate film by laser drilling. Deionized water is injected into the channels with a microinjection pump. The flow rate is 5µL/min. There is no damage to the channel.
4. Conclusions
(1) The groove with a width from several dozen pm to several hundred pm is created on the resin layer without any damage on the substrate by ablation processing with an ultraviolet laser.
(2) A heat-hardening resin film can be used to maintain 100% of the channel space for fluid flow.
(3) Fresh blood flows easily through the channels.
CHAPTER 2PHOTOPOLYMERIZED POLY (ETHYLENE) GLYCOL DIACRYLATE (PEGDA) MICROFLUIDIC DEVICES
Amy Butterworth, Maria del Carmen Lopez Garcia and David Beebe Department of Biomedical Engineering, University of Wisconsin 1550 Engineering Drive, 53704 Madison WI, USA
Abstract
As microfluidic applications in cell biology move beyond diagnostic assays to long term culture and production, alternative materials will be needed. Poly (ethylene) glycol (PEG) has been widely utilized as a biocompatible polymer due to its hydrophilicity and non-fouling behavior. Diacrylated, PEG can be photopolymerized using the microfluidic tectonics platform (µFT) and provides a more biocompatible alternative to previous polymers used. The ability of this monomer to be polymerized and patterned into channels for micro-cell culture was evaluated. Also, the biocompatibility of the polymer was assessed using FT-IR and cell interaction studies with the unpolymerized components.
Keywords: Microfluidic tectonics, biocompatibility, photopolymerization, poly (ethylene) glycol (PEG)
1. Introduction
Poly (ethylene) glycol (PEG) has been widely utilized as a biocompatible polymer due to its hydrophilicity and non-fouling behavior. PEG resists protein absorption and has been used as a coating or as a polymer substrate to prevent or control cell adhesion and adsorption of proteins for over a decade. PEG has been used previously in bioMEMS-related technologies as a coating or as a co-monomer for purposes such as polymerizing cells in gels. Diacrylated, PEG can be photopolymerized using the microfluidic tectonics platform (µFT) and provides a more biocompatible alternative to previous polymers used. The ability to incorporate PEG as a construction material for microfluidic systems will allow the unique properties of PEG to be exploited for a variety of cell-based experiments. Examples include using in-situ polymerized porous PEG gels as selective diffusional barriers to replace media changes during cell culture, or copolymerizing with a hydrolytically degradable monomer for controlled release of biomolecules of interest.
2. Fabrication and Biocompatibility Analysis
The biocompatibility of this polymer will be partially dependent on the complete polymerization of the monomer while using a minimal concentration of photoinitiator. The typical concentration of photoinitiator used in these experiments was 0.05 wt%, although lower percentages (below 0.01 wt%) can be polymerized but exhibit more swelling. To verify the degree of polymerization, FTIR studies were done, comparing the spectra of the polymer with 0.1 wt% photoinitiator (Fig. la) to that with 0.05 wt% (Fig. 1b). The polymerization of diacrylates reduces the magnitude of the carbon-carbon double bond peak (shown in Fig. 1) and is expected to decrease with increasing photoinitiator concentration as shown. FTIR measurements allow one to find a balance between concentration of photoinitiator and degree of polymerization that minimizes the cytotoxicity of the devices, while maintaining good patterning capabilities. After UV sterilization before use in cell culture, this peak decreased slightly. Straight channels were patterned to test the patterning capabilities, with widths ranging from 175pm to 1,000pm in 250 pm high devices (Fig. 2). Good resolution of less than 10pm was achieved which is comparable to that achieved with poly (IBA). A valve mask currently in use for creating the substrate for a hydrogel actuated valve was also patterned in PEGdA with relative ease [5]. These two materials show similar capabilities although the PEGdA devices produce more rounded features.
Since our intended use of the PEG channels is long term (weeks) cell culture, the long term capability of the material was tested to ensure no failure occurred due to the PEGdA swelling. Swelling of the PEGdA material did cause device failure more frequently as the percentage of photo initiator decreased (from 0.05 wt% to 0.01 wt%) and exposure intensities decreased (from 20 mW/cm2 to 10 mW/cm2). The molecular weight of the PEGdA was reduced from 575 MW to 258 MW, which showed significantly reduced swelling and produced devices which could be incubated at 37°C without immediate failure. Multiple photoinitiators 4-(2-hydroxyethoxy)phenyl-(2 -hydroxy-2-propyl) ketone (Irgacure 2959, Ciba, Inc.) and biacylphosphine oxide (BAPO, Iragure 819, Ciba, Inc.) were also studied. The former has commonly been used for photopolymerization of cells in gels and has shown to be more biocompatible than many photoinitiators. The latter has a higher efficiency (the absorption band extends to 400nm) at the wavelengths of exposure, so lower concentrations were needed. Successful polymerization was demonstrated with both compounds, although BAPO-initiated devices proved to be more resistant to swelling most likely due to the faster reaction kinetics causing denser gels.
4. Biocompatibility
Devices were created with the optimized prepolymer mixtures and exposures with 1,000µm straight channels and incubated with DPBS at 37°C. When externally reinforced with adhesive, these devices are suitable for cell culture, surviving for more than one week without failure due to swelling of the polymer. The cellular response to the presence of the monomer and photoinitiator in the media was evaluated. A concentration of 10 µM PEGdA caused significant reduction in NMuMG cell adhesion, while 1µM did not prevent adhesion, although cell morphology was slightly different than the controls. Cells with PEGdA in the media that did attach to the surface remained rounded in colonies rather than spreading as expected for epithelial cells. Due to very low solubility of BAPO in the media, quantitative results were not obtained, although the presence of BAPO did cause cell death in media with the maximum soluble amount of BAPO. It is clear that further optimization of the polymerization technique and prepolymer mixture is needed to ensure minimal concentrations of prepolymer components remain after polymerization and washing in order to maximize biocompatibility.
CHAPTER 3A FLOW-THROUGH SHEAR-TYPE MICROFILTER CHIP FOR SEPARATING PLASMA and VIRUS PARTICLES FROM WHOLE BLOOD
Levent Yobas, Ee-Ling Gui, Hongmiao Ji, Jing Li, Yu Chen, Wing-Cheong Hui, Siti Rafeah Binte Mohamed Rafe, Sanjay Swarup, Sek-Man Wong, Tit-Meng Lim Chew-Kiat Heng
Institute of Microelectronics, 11 Science Park Road, Singapore Science Park II, 117685, Singapore Nanyang Technological University, School of Materials Engineering, 639798, Singapore National University of Singapore, Department of Pediatrics, 119074, Singapore National University of Singapore, Department of Biological Sciences, 117543, Singapore
Abstract
A flow-through shear-type microfilter chip has been proposed for the purpose of separating plasma and virus particles from whole blood. The microfilter chips have been fabricated in three different design configurations by silicon micromachining and tested for their percent efficiency of separating plasma from diluted blood samples. One of the designs has been further demonstrated to be capable of isolating virus particles from a spiked sample of whole blood.
Keywords: Microfilter, shear filter, virus, plasma, sample preparation
1. Introduction
Recent epidemics such as Severe Acute Respiratory Syndrome (SARS) have highlighted the importance of an automated sample preparation for virus and pathogen detection. Detection of extracelullar viruses from blood usually requires separation of plasma or serum containing virus particles from cellular components. This is because hemoglobin from red blood cells (RBC) is known to inhibit nucleic acid amplification while nucleic acids in white blood cells (WBC) can contribute to background noise during detection. Typically, plasma is obtained from whole blood by a centrifugation step. Nevertheless, centrifugation is not amenable to automation. An alternative approach is filtering plasma based on size exclusion of cells. Most viruses are less than 1 µm while most RBC and WBC remain larger than 2µm.
2. Microfilter Chip
The proposed micro filter concept and structure are diagrammatically shown in Fig. 1. The chip contains a chamber etched about 65-pm deep into silicon by deep reactive ion etching and capped with a glass wafer by anodic bonding. Plasma can be collected through anisotropically-etched backside holes in silicon located at two diagonal comers. At the other comers, backside holes allow blood to flow in and out of the chip through a meander type channel defined by silicon pillars. As blood flows inside the channel, plasma can escape through narrow slits between pillars due to combined action of capillary forces and pressure gradient. Nominal gap between the pillars is about 1.6pm wide, which can retain most blood cells but allow passage of virus particles. The microfilter chips have been fabricated in three design configurations mainly differing in chip size and shape of the meander-type channel (Table I).
3. Experimental Results & Discussion
Fig. 2 shows on-chip collection of plasma escaping through the slits between pillars as the anticoagulant-treated whole blood flows through the meander-type channel. Anticoagulant-treated blood was pumped through the chips at 10µl/min and at different dilutions of phosphate buffered saline (PBS) solution. RBC counts in the blood pumped in (RBCblood) and the plasma collected (RBCplasma) were obtained by a hemocytometer. Table I shows volume of the collected plasma samples and percent efficiency of each microfilter chip (% EF) as calculated by:
EF = [1 - (RBCplasma/RBCblood)]x 100 (1)
As shown, chips based on any of the three designs had higher than 99% efficiency for the Blood:PBS ratio of 25:75. The efficiency deteriorated with an increase in the blood:PBS ratio but stayed above 90% for all three microfilter chips.
Further, experiments were conducted to test whether the plasma filtered by the microfilter chips can be used for detection of virus particles in blood. Anticoagulant-treated whole blood at a volume of 140µl was spiked with virus (Cymbidium Mosaic Virus) suspension in water at a volume of 70µl and concentration of 0.26µg/µl. Approximately, 180|il of the spiked blood was pumped through microfilter #1 at 10µl/min. The plasma filtrate was used for extraction of viral RNA via a commercial kit [3] and amplified by reverse transcription polymerase chain reaction (RT-PCR). The amplified products were separated by agarose gel electrophoresis and ethidium bromide-stained products were visualized on a UV transilluminator. As can be seen in Fig. 3, viral RNA from the plasma filtered by microfilter chip #1 could be amplified, demonstrating a successful substitute for the conventional centrifugation step.
(Continues...)
Excerpted from Micro Total Analysis Systems 2004 Volume 2 by Thomas Laurell, Johan Nilsson, Klavs Jensen, D. Jed Harrison, Jörg P. Kutter. Copyright © 2004 The Royal Society of Chemistry. Excerpted by permission of The Royal Society of Chemistry.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.
"About the title" may belong to another edition of this title.
Shipping rates from Germany to U.S.A.
| Item | 7 to 10 business days | 5 to 7 business days |
|---|---|---|
| First item | US$ 48.75 | US$ 66.82 |
Payment methods
- Bank Wire Transfer
- Check
- Paypal
Store description
Das Unternehmen AHA-BUCH GmbH: Seit der Gründung von AHA-BUCH im Juli 2005 ist unser Hauptziel, zufriedenen Kunden so schnell und so preisgünstig wie möglich ihren Bücherwunsch zu erfüllen. Unsere Firma beschäftigt 16 Mitarbeiter, die nur ein Ziel kennen: den Kunden und seine Wünsche! Auf über 3700 m2 Fläche haben wir über 100.000 Bücher, Modernes Antiquariat und Spiele auf Lager.
Specialty
Kinderbücher & Kinderhör Casetten, German Books, Software, Natur & Tiere, Ratgeber, Sachbücher, Englische Bücher, Medizin & Gesundheit, Universität & StudiumSeller's business information
AHA-BUCH GmbH
Garlebsen 48
Einbeck, Germany 37574
Terms of sale
General Terms and Conditions and Customer Information / Privacy Policy
I. General Terms and Conditions
§ 1 Basic provisions
(1) The following terms and conditions apply to all contracts that you conclude with us as a provider (AHA-BUCH GmbH) via the Internet platforms AbeBooks and/or ZVAB. Unless otherwise agreed, the inclusion of any of your own terms and conditions used by you will be objected to
(2) A consumer within the meaning of the following regulations is any natural person who concludes a legal transaction for purposes that can predominantly be attributed neither to their commercial nor their independent professional activity. An entrepreneur is any natural or legal person or a partnership with legal capacity who, when concluding a legal transaction, acts in the exercise of his independent professional or commercial activity.
§ 2 Conclusion of the contract
(1) The object of the contract is the sale of goods.
(2) If an article is listed by us at AbeBooks or ZVAB, the activation of the offer page at AbeBooks or ZVAB constitutes the binding offer to conclude a contract under the conditions contained in the article page.
(3) The contract is concluded via the online shopping cart system as follows:
The goods intended for purchase are stored in the "shopping cart". Via the corresponding button in the navigation bar you can call up the "shopping cart" and make changes there at any time.
After calling up the "Checkout" page and entering the personal data as well as the payment and shipping conditions, all order data will be displayed again on the order overview page.
Before sending the order, you have the option of checking all information again, changing it (also via the "back" function of the Internet browser) or cancelling the purchase.
By submitting the order via the "Buy now" button, you declare the acceptance of the offer in a legally binding manner, whereby the contract is concluded.
(4) The processing of the order and transmission of all information required in connection with the conclusion of the contract is partly automated by e-mail. You must therefore ensure that the e-mail address you have stored with us is correct, that the receipt of the e-mails is technically ensured and, in particular, that spam filters do not prevent it.
§ 3 Right of retention, retention of title
(1) You can only exercise a right of retention if it concerns claims from the same contractual relationship.
(2) The goods remain our property until full payment of the purchase price.
§ 4 Warranty
(1) The statutory warranty rights exist.
(2) In the case of used goods, the warranty period is one year from delivery of the item, deviating from the statutory regulation. The shortening of the deadline does not apply:
- culpably caused damages attributable to us from injury to life, limb or health and in the case of other damages caused intentionally or through gross negligence;
- insofar as we have fraudulently concealed the defect or have assumed a guarantee for the quality of the item.
(3) As a consumer, you are requested to check the item immediately upon delivery for completeness, obvious defects and transport damage and to inform us and the freight forwarder of any complaints as soon as possible. If you do not comply with this, this will have no effect on your statutory warranty claims.
§ 5 Choice of law, place of performance, place of jurisdiction
(1) German law shall apply. In the case of consumers, this choice of law shall only apply insofar as this does not withdraw the protection afforded by mandatory provisions of the law of the state of the consumer's habitual residence (principle of favourability).
(2) The place of performance for all services arising from the existing business relationships with us as well as the place of jurisdiction is our registered office, insofar as you are not a consumer, but a merchant, a legal entity under public law or a special fund under public law. The same applies if you do not have a general place of jurisdiction in Germany or the EU or if the domicile or habitual residence is not known at the time the action is brought. The right to appeal to the court at another statutory place of jurisdiction remains unaffected by this.
(3) The provisions of the UN Convention on Contracts for the International Sale of Goods shall expressly not apply.
II. Customer Information
- Identity of the Seller
AHA-BUCH GmbH
Garlebsen 48
D-37574 Einbeck
Germany
Telephone: 055639996039
E-mail: abebooks@aha-buch.de.
Alternative dispute resolution:
The European Commission provides a platform for out-of-court online dispute resolution (ODR platform), which can be accessed under https://ec.europa.eu/odr.
- Information on the conclusion of the contract
The technical steps for the conclusion of the contract, the conclusion of the contract itself and the correction options are carried out in accordance with the provisions "Conclusion of the contract" of our General Terms and Conditions (Part I.).
- Contract language, contract text storage
3.1. The contract language is german.
3.2. The complete text of the contract will not be stored by us. Before sending the order, the contract data can be printed out or electronically saved via the print function of the browser. After receipt of the order by us, the order data, the legally prescribed information for distance contracts and the General Terms and Conditions will be sent to you again by e-mail.
- Essential characteristics of the goods or services
The essential characteristics of the goods and/or services can be found in the respective offer.
- Prices and terms of payment
5.1. The prices stated in the respective offers as well as the shipping costs represent total prices. They include all price components including all applicable taxes.
5.2. The shipping costs incurred are not included in the purchase price. They can be called up via a correspondingly designated button on our website or in the respective offer, are shown separately in the course of the ordering process and are to be borne by you in addition, unless free shipping has been promised.
5.3. If the delivery is made to countries outside the European Union, we may incur additional costs for which we are not responsible, such as.B customs duties, taxes or money transfer fees (transfer or exchange rate fees of the credit institutions), which are to be borne by you. Any costs incurred for the transfer of money shall also be borne by you in cases where the delivery is made to an EU member state, but the payment was initiated outside the European Union.
5.4. The payment methods available to you are indicated under a corresponding button on our website or in the respective offer.
5.5. Unless otherwise stated for the individual payment methods, the payment claims from the concluded contract are due for payment immediately.
- Terms of delivery
6.1. The terms of delivery, the delivery date and, if applicable, existing delivery restrictions can be found under a correspondingly designated button on our website or in the respective offer.
Insofar as no other deadline is specified in the respective offer or under the correspondingly designated button, the delivery of the goods will take place within 3-5 days after conclusion of the contract (in the case of agreed advance payment, however, only after the time of your payment instruction).
6.2. Insofar as you are a consumer, it is regulated by law that the risk of accidental loss and accidental deterioration of the sold item during dispatch shall only pass to you upon handover of the goods, regardless of whether the shipment is insured or uninsured. This does not apply if you have independently commissioned a transport company not named by the entrepreneur or a person otherwise designated to carry out the shipment.
- Statutory liability for defects
Liability for defects is governed by the "Warranty" provision in our General Terms and Conditions (Part I).
last update: 01/06/2022
Privacy policy
Unless otherwise stated below, the provision of your personal data is neither required by law or contract, nor is it necessary for the conclusion of a contract. You are not obliged to provide the data. Failure to provide this will have no consequences. This only applies if no other information is provided in the subsequent processing operations.
Collection, processing and disclosure of personal data when placing orders
When ordering, we collect and process your personal data only to the extent necessary to fulfil and process your order and to process your enquiries. The provision of the data is necessary for the conclusion of the contract. Failure to provide this provision means that no contract can be concluded. The processing takes place on the basis of Art. 6 para. 1 lit.b GDPR and is necessary for the performance of a contract with you.
Your data will be passed on, for example, to the shipping companies and dropshipping providers selected by you, payment service providers, service providers for order processing and IT service providers.
In all cases, we strictly observe the legal requirements. The scope of data transmission is limited to a minimum.
Duration of storage
After completion of the contract, the data will first be stored for the duration of the warranty period, then taking into account legal, in particular tax and commercial retention periods and then deleted after expiry of the period, unless you have consented to further processing and use.
Rights of the data subject
If the legal requirements are met, you have the following rights under Articles 15 to 20 GDPR: Right to information, to correction, to erasure, to restriction of processing, to data portability.
In addition, pursuant to Article 21 (1) GDPR, you have the right to object to processing based on Article 6 (1) f GDPR and to processing for direct marketing purposes.
Contact us on request. The contact details can be found in our imprint.
Right to lodge a complaint with the supervisory authority
In accordance with Article 77 GDPR, you have the right to complain to the supervisory authority if you believe that the processing of your personal data is not lawful.
Right to object
If the personal data processing listed here is based on our legitimate interest pursuant to Art. 6 para. 1 lit. f GDPR, you have the right to object to this processing at any time with effect for the future for reasons arising from your particular situation.
Shipping terms
We ship your order after we received them
for articles on hand latest 24 hours,
for articles with overnight supply latest 48 hours.
In case we need to order an article from our supplier our dispatch time depends on the reception date of the articles, but the articles will be shipped on the same day.
Our goal is to send the ordered articles in the fastest, but also most efficient and secure way to our customers.