Model of the Response Function of CUORE Bolometers
Marco Vignati
Sold by Buchpark, Trebbin, Germany
AbeBooks Seller since September 30, 2021
Used - Hardcover
Condition: Hervorragend
Ships from Germany to U.S.A.
Quantity: 1 available
Add to basketSold by Buchpark, Trebbin, Germany
AbeBooks Seller since September 30, 2021
Condition: Hervorragend
Quantity: 1 available
Add to basketZustand: Hervorragend | Sprache: Englisch | Produktart: Bücher | Large mass bolometers are used in particle physics experiments to search for rare processes, like neutrinoless double beta decay and dark matter interactions.In the next years the CUORE experiment (a 1 Ton detector composed by 1000 crystals of TeO2 operated as bolometers in a large cryostat at 10mK) will be the particle physics experiment with the highest chance of discovering the Majorana neutrino, a long standing and yet fundamental question of particle physics. The study presented in this book was performed on the bolometers of the CUORE experiment. The response function of these detectors is not linear in the energy range of interest, and it changes with the operating temperature, worsening the performances. The nonlinearity appeared to be dominated by the thermistor and the biasing circuit used to read the bolometer, and was modeled using few measurable parameters.A method to obtain a linear response is the result of this work. It allows a great improvement of the detector operation and data analysis. With a foreword by Fernando Ferroni.
Seller Inventory # 10523956/1
Large mass bolometers are used in particle physics experiments to search for rare processes, like neutrinoless double beta decay and dark matter interactions.
In the next years the CUORE experiment (a 1 Ton detector composed by 1000 crystals of TeO2 operated as bolometers in a large cryostat at 10mK) will be the particle physics experiment with the highest chance of discovering the Majorana neutrino, a long standing and yet fundamental question of particle physics.
The study presented in this book was performed on the bolometers of the CUORE experiment. The response function of these detectors is not linear in the energy range of interest, and it changes with the operating temperature, worsening the performances. The nonlinearity appeared to be dominated by the thermistor and the biasing circuit used to read the bolometer, and was modeled using few measurable parameters.
A method to obtain a linear response is the result of this work. It allows a great improvement of the detector operation and data analysis.
With a foreword by Fernando Ferroni.
"About this title" may belong to another edition of this title.
| Order quantity | 60 to 60 business days | 60 to 60 business days |
|---|---|---|
| First item | US$ 124.67 | US$ 154.36 |
Delivery times are set by sellers and vary by carrier and location. Orders passing through Customs may face delays and buyers are responsible for any associated duties or fees. Sellers may contact you regarding additional charges to cover any increased costs to ship your items.