Optimization of Paced AV Delay Using Atrial Contribution Index
Language: English
Published by Nova Science Publishers, Incorporated, 2008
- Softcover
- Used

Seller: Books Puddle, Woodside, NY, U.S.A.Books Puddle
4-star seller
AbeBooks seller since November 22, 2018
Softcover
Condition: Used
US$ 54.12
US$ 3.99 shipping
Ships within U.S.A.
Quantity: 1 available
Add to basketFree 30-day returns
Item description from seller
pp. viii + 81.
Seller Inventory # 264600570
- Title
- Optimization of Paced AV Delay Using Atrial Contribution Index
- Author
- Jiri Kvasnicka Miroslav Mestan
- Publisher
- Nova Science Publishers, Incorporated
- Publication year
- 2008
- Condition
- Used
- Binding
- Soft cover
- Language
- English
- ISBN 10
- 1604566043
- ISBN 13
- 9781604566048
The hemodynamic effect of the atria on the net performance of the heart is called atrial contribution (AC). AC is either linked to ventricular filling or to the systolic function of the heart, i.e. to the systolic volume or cardiac output. Several noninvasive methods for the quantification of AC are described in literature but none of them are routinely used in cardiac pacing centres due to the time-consuming nature of the methods, the limited reproducibility of measured values and observer dependency. The aim of these studies was to develop a method for determining optimal AV delay in patients treated by dual chamber pacing using an index (ACSp) that quantifies atrial contribution to the systolic volume of the left ventricle. The new method is based on the quantitative analysis of a beat to beat decrease in the amplitude of the pulse oximetry signal (SpO2). The change in the amplitudes is induced by a sudden drop of the stimulus to the right atrium, while maintaining the rate of ventricular stimuli at a constant level. The obtained ACSp is given as a percentage of the pulse amplitude of SpO2. The method is independent of the observer, non-invasive and relatively fast. In a group of 47 patients, remarkable similarities between ACSp and another atrial contribution index estimated using the tracings of invasively registered aortal pressure were demonstrated. In all investigated AV intervals of 50 to 250 ms, significant inter-individual variability of ACSp was discovered. The poorest hemodynamic effect was seen at AV delay of 50 ms (median ACSp of 10.4 % from 97 subjects). In 150 subjects, the following values of ACSp were obtained at AV delay of 200 ms: median 30 %, minimum 3.6 % and maximum 80.4 %. An increase in ACSp follows reduction of preload induced by administration of furosemide. This suggests that when preload decreases cardiac output is preserved by an increase in AC enforced by sympathetic activation.
"Synopsis" may belong to another edition of this title.
Books Puddle
Woodside, NY, U.S.A.
4-star seller
AbeBooks seller since November 22, 2018
Shipping rates within U.S.A.
| Item | 12 to 19 business days | 12 to 14 business days |
|---|---|---|
| First item | US$ 3.99 | US$ 6.99 |
Payment methods
Store description
I mainly carry imported books from South East Asia / South Asia for readers of all Age Groups.
Specialty
South Asian and South East Asian Culture, Religion, Art etcSeller's business information
PLETOS INC
6931 51st Avenue, WOODSIDE
Woodside, NY U.S.A. 11377
Terms of sale
We accept return for those books which are received damaged. Though we take appropriate care in packing to avoid such situation.