Planning, Design and Optimization of Distribution System for Affected Area of Upper Karnali Hydropower Project
Language: English
Published by Grin Publishing, 2017
- Softcover
- New

Seller: California Books, Miami, FL, U.S.A.California Books
5-star seller
AbeBooks seller since October 27, 2023
Softcover
Condition: New
US$ 45.00
US$ 3.00 shipping
Ships within U.S.A.
Quantity: Over 20 available
Add to basketFree 30-day returns
Seller Inventory # I-9783668559806
- Title
- Planning, Design and Optimization of Distribution System for Affected Area of Upper Karnali Hydropower Project
- Author
- Shrestha, Ashish
- Publisher
- Grin Publishing
- Publication year
- 2017
- Condition
- New
- Binding
- Soft cover
- Language
- English
- ISBN 10
- 3668559805
- ISBN 13
- 9783668559806
Master's Thesis from the year 2017 in the subject Engineering - Mechanical Engineering, grade: 4, Kathmandu University (School of Engineering), course: Masters' Program in Planning and Operation of Energy System, language: English, abstract: This study illustrates the best approach for energy access to the affected area of a 900 MW Upper Karnali Hydropower Project (UKHPP) located in Western Nepal. As per concession agreement executed between the developer of UKHPP and the Government of Nepal, the developer will develop 2 MW power plant at the toe of the dam using the environmental release discharge to electrify the affected area of UKHPP. First, the study looks at the optimization of the electric grid network in the project affected area, using Kruskal's algorithm. The optimization is carried out so that access to electricity is guaranteed to possible load centers in the affected area to the extent possible in technical and financial feasible manner. This study is an attempt to connect the possible load centers through an optimum network design based on demography, topography, technical feasibility and socio-economic factors. The study focuses on the design of the electrical network based on a least distance path between the identified nodes. The designed network is based on the survey using GIS, Topographical maps, and satellite views from Google map. A total of 57 load centers are identified connected through a grid 144.59 km in length. Similarly, taking n=4 sample, the total length of 220V distribution system is estimated to be 417.24 km. After that, the study focuses on the Static Load Flow Analysis (SLFA) by developing a framework based on Conventional Newton- Raphson method to analyze the network's parameters. The result obtained from the analysis is compared with the results of standard 33-bus radial feeder system and forward/backwards (f/b) sweep based algorithm using statistical analysis. The standard error is accepted for the 95% level of significance. It
"Synopsis" may belong to another edition of this title.
California Books
Miami, FL, U.S.A.
5-star seller
AbeBooks seller since October 27, 2023
Shipping rates within U.S.A.
| Item | 3 to 7 business days | 2 to 5 business days |
|---|---|---|
| First item | US$ 3.00 | US$ 17.00 |
Payment methods
Store description
We have 20 years experience selling books worldwide! Friendly customer support. Your satisfaction guaranteed!
Specialty
All authorized categoriesSeller's business information
Miramar International Services LLC
FL, U.S.A.
Terms of sale
www.californiabooks.com
Shipping terms
www.californiabooks.com