Isbn: 9786139912759 - Hybrid Reactive Power Compensation System for Low Voltage Applications: Three-phase Hybrid Statcom (static Synchronous Compensator) Prototype Design & Validation in Hardware in Loop (6 results)

ISBN
Refine with Advanced Search

Refine your search

  • Books (6)

  • New (6)

to

Custom price range (US$)

to

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2018

    613991275X / 9786139912759

    • Softcover

    Seller: Revaluation Books, Exeter, United KingdomRevaluation Books

    5-star seller
    Contact seller

    Condition: New

    US$ 108.94

    US$ 13.39 shipping 
    Ships from United Kingdom to U.S.A.

    Quantity: 1 available

    Paperback. Condition: Brand New. 100 pages. 8.66x5.91x0.23 inches. In Stock.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2018

    613991275X / 9786139912759

    • Softcover

    Seller: preigu, Osnabrück, Germanypreigu

    5-star seller
    Contact seller

    Condition: New

    US$ 56.73

    US$ 80.40 shipping 
    Ships from Germany to U.S.A.

    Quantity: 5 available

    Taschenbuch. Condition: Neu. Hybrid Reactive Power Compensation System for Low Voltage Applications | Three-phase Hybrid STATCOM (Static Synchronous Compensator) prototype Design & Validation in Hardware in Loop | Umer Mushtaq | Taschenbuch | 100 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139912759 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

  • Language: English

    Published by LAP LAMBERT Academic Publishing Okt 2018, 2018

    613991275X / 9786139912759

    • Softcover
    • Print on Demand

    Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

    5-star seller
    Contact seller

    Condition: New

    US$ 64.95

    US$ 26.42 shipping 
    Ships from Germany to U.S.A.

    Quantity: 2 available

    Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents a design of three-phase hybrid STATCOM prototype (Static synchronous compensator) that provide reactive power for power factor correction in the low voltage distribution system. The system consists of capacitor banks and an inverter. This system has a master controller that controls the RP reference of inverter and switching of power capacitors with the capability to reduce capacitors switching events to increase the life of power components. There are three key objectives: theoretical, simulation study and experimental work. The theoretical part discusses the harmonics mitigation, inverter topology and control, filter topology and the performance of the overall system. Simulation is performed on Matlab/Simulink platform, for experimental verification a prototype is also developed in the lab to prove the effectiveness of the designed filter, controllers and grid synchronization method. The Opal RT-lab hardware in the loop is used for hardware testing, which provides a good solution for the analysis of design and laboratory prototype implementation. 100 pp. Englisch.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2018

    613991275X / 9786139912759

    • Softcover
    • Print on Demand

    Seller: moluna, Greven, Germanymoluna

    5-star seller
    Contact seller

    Condition: New

    US$ 53.77

    US$ 56.27 shipping 
    Ships from Germany to U.S.A.

    Quantity: Over 20 available

    Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Mushtaq UmerUmer Mushtaq is a PhD researcher at the Technical University of Delft, Netherlands. He received this master degree in Sustainable Transportation and Electrical Power Systems from the University of Oviedo Spain and the Un.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2018

    613991275X / 9786139912759

    • Softcover
    • Print on Demand

    Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

    5-star seller
    Contact seller

    Condition: New

    US$ 93.52

    US$ 35.03 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book presents a design of three-phase hybrid STATCOM prototype (Static synchronous compensator) that provide reactive power for power factor correction in the low voltage distribution system. The system consists of capacitor banks and an inverter. This system has a master controller that controls the RP reference of inverter and switching of power capacitors with the capability to reduce capacitors switching events to increase the life of power components. There are three key objectives: theoretical, simulation study and experimental work. The theoretical part discusses the harmonics mitigation, inverter topology and control, filter topology and the performance of the overall system. Simulation is performed on Matlab/Simulink platform, for experimental verification a prototype is also developed in the lab to prove the effectiveness of the designed filter, controllers and grid synchronization method. The Opal RT-lab hardware in the loop is used for hardware testing, which provides a good solution for the analysis of design and laboratory prototype implementation.

  • Language: English

    Published by LAP LAMBERT Academic Publishing Okt 2018, 2018

    613991275X / 9786139912759

    • Softcover
    • Print on Demand

    Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

    5-star seller
    Contact seller

    Condition: New

    US$ 64.95

    US$ 68.92 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book presents a design of three-phase hybrid STATCOM prototype (Static synchronous compensator) that provide reactive power for power factor correction in the low voltage distribution system. The system consists of capacitor banks and an inverter. This system has a master controller that controls the RP reference of inverter and switching of power capacitors with the capability to reduce capacitors switching events to increase the life of power components. There are three key objectives: theoretical, simulation study and experimental work. The theoretical part discusses the harmonics mitigation, inverter topology and control, filter topology and the performance of the overall system. Simulation is performed on Matlab/Simulink platform, for experimental verification a prototype is also developed in the lab to prove the effectiveness of the designed filter, controllers and grid synchronization method. The Opal RT-lab hardware in the loop is used for hardware testing, which provides a good solution for the analysis of design and laboratory prototype implementation.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 100 pp. Englisch.