Two Phase Ejector Performance Enhancer by Katam Ganesh (8 results)

Author: 
Title: 
Refine with Advanced Search

Refine your search

  • Books (8)

  • New (8)

to

Custom price range (US$)

to

  • Condition: New

    US$ 82.25

    US$ 13.27 shipping 
    Ships from United Kingdom to U.S.A.

    Quantity: 1 available

    Paperback. Condition: Brand New. 80 pages. 8.66x5.91x0.19 inches. In Stock.

  • Language: English

    Published by LAP LAMBERT Academic Publishing Aug 2019, 2019

    6200284148 / 9786200284143

    • Softcover
    • Print on Demand

    Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

    5-star seller
    Contact seller

    Condition: New

    US$ 46.25

    US$ 25.88 shipping 
    Ships from Germany to U.S.A.

    Quantity: 2 available

    Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System. 80 pp. Englisch.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Mär 2026, 2026

    6209691021 / 9786209691027

    • Softcover
    • Print on Demand

    Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

    5-star seller
    Contact seller

    Condition: New

    US$ 50.89

    US$ 25.88 shipping 
    Ships from Germany to U.S.A.

    Quantity: 2 available

    Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware 80 pp. Englisch.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2019

    6200284148 / 9786200284143

    • Softcover
    • Print on Demand

    Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

    5-star seller
    Contact seller

    Condition: New

    US$ 46.80

    US$ 39.39 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2026

    6209691021 / 9786209691027

    • Softcover
    • Print on Demand

    Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

    5-star seller
    Contact seller

    Condition: New

    US$ 51.49

    US$ 39.39 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2019

    6200284148 / 9786200284143

    • Softcover
    • Print on Demand

    Seller: moluna, Greven, Germanymoluna

    5-star seller
    Contact seller

    Condition: New

    US$ 39.70

    US$ 55.13 shipping 
    Ships from Germany to U.S.A.

    Quantity: Over 20 available

    Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Katam Ganesh BabuDr. Ganesh Babu Katam born on 24th August 1983 in Kurnool (D), Andhra Pradesh, India. In 2009 he completed B.Tech in Mechanical Engg (IPE) from G. Pulla Reddy Engg College Kurnool. In the year 2011 received M.Tech de.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Aug 2019, 2019

    6200284148 / 9786200284143

    • Softcover
    • Print on Demand

    Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

    5-star seller
    Contact seller

    Condition: New

    US$ 46.25

    US$ 67.52 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Mär 2026, 2026

    6209691021 / 9786209691027

    • Softcover
    • Print on Demand

    Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

    5-star seller
    Contact seller

    Condition: New

    US$ 50.89

    US$ 67.52 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch.…