Molecular Alternatives to Indicator and Pathogen Detection (Paperback)
Language: English
Published by IWA Publishing, London, 2006
- First Edition
- Softcover
- New

Seller: Grand Eagle Retail, Bensenville, IL, U.S.A.Grand Eagle Retail
AbeBooks seller since October 12, 2005
Condition: New
US$ 200.10
Quantity: 1 available
Add to basketItem description from seller
Paperback. Microbial quality of water is a prime public health concern in today's world. To protect public health, the World Health Organization and the U.S. Environmental Protection Agency have established microbial pollution indicator standards and recommended routine monitoring of water for both total and fecal coliforms. However, the adequacy of current water quality standards to indicate the presence or absence of human pathogens is still questionable. For example, human viruses are more resistant to sewage treatment processes and environmental conditions than bacterial indicators and therefore may pose a substantial threat. It is now recognized that the absence, or a low concentration, of indicator organisms in water may not adequately reflect the absence of human viruses. In our previous study of southern California coastal waters, we found over 30% of coastal waters tested contained human viruses, and the presence of these viruses did not correlate with an elevated level of bacterial indicators (Jiang et al. 2000). The goal of this research is to develop and validate a molecular method for rapid and specific detection of microbial contaminants including human viruses and bacterial indicators in treated sewage effluents and receiving waters. Microbial quality of water is a prime public health concern in today's world. To protect public health, the World Health Organization and the U.S. Environmental Protection Agency have established microbial pollution indicator standards and recommended routine monitoring of water for both total and fecal coliforms (Dufour, 1984, U.S. EPA 1986,1994, WHO 1993). However, the adequacy of current water quality standards to indicate the presence or absence of human pathogens is still questionable. For example, human viruses are more resistant to sewage treatment processes and environmental conditions than bacterial indicators and therefore may pose a substantial threat. It is now recognized that the absence, or a low concentration, of indicator organisms in water may not adequately reflect the absence of human viruses. In our previous study of southern California coastal waters, we found over 30% of coastal waters tested contained human viruses, and the presence of these viruses did not correlate with an elevated level of bacterial indicators (Jiang et al. 2000). The goal of this research is to develop and validate a molecular method for rapid and specific detection of microbial contaminants including human viruses and bacterial indicators in treated sewage effluents and receiving waters. Research Outcomes An extensive search and review of current state of technology for molecular alternatives to indicator and viral pathogen detection was conducted. The results indicate that although real-time PCR methods have been widely applied in the clinical research for detection of human viruses, environmental application of this method is very limited. In addition, there is an urgent need for a method for efficient concentration and purification of human viruses in complex environmental matrixes. During this study, we have designed, tested and optimized real-time quantitative PCR method using specific and degenerate primers and probes targeting at adenoviruses and enterococci, respectively. Experimental testing of real time PCR primers and probes for adenoviruses demonstrated reproducible results at efficiency greater than 90% over a 5-log dynamic range of target concentration. The enterococci real time PCR was efficient at 99% of the time and over a 7-log dynamic range of target concentration. Application of these methods to sewage effluents and coastal waters demonstrated that real-time PCR methods are more sensitive than culturing methods at detection of targets, suggesting a great potential for real-time quantification of microbial contaminants in environments. However, real-time PCR based meth Shipping may be from multiple locations in the US or from the UK, depending on stock availability.…
Seller Inventory # 9781843397359
- Title
- Molecular Alternatives to Indicator and Pathogen Detection (Paperback)
- Author
- S.C. Jiang
- Publisher
- IWA Publishing, London
- Publication year
- 2006
- Condition
- new
- Binding
- Paperback
- Language
- English
- ISBN 10
- 1843397358
- ISBN 13
- 9781843397359
- Edition
- 1st Edition
"Synopsis" may belong to another edition of this title.
Grand Eagle Retail
Bensenville, IL, U.S.A.
AbeBooks seller since October 12, 2005
Shipping rates within U.S.A.
| Item | 6 to 14 business days | 6 to 16 business days |
|---|---|---|
| First item | US$ 0.00 | US$ 0.00 |
Payment methods
Seller's business information
APOLLO ONLINE CORP.
605 Geddes Street
Wilmington, DE U.S.A. 19805
Terms of sale
We guarantee the condition of every book as it¿s described on the Abebooks web sites. If you¿ve changed
your mind about a book that you¿ve ordered, please use the Ask bookseller a question link to contact us
and we¿ll respond within 2 business days.
Books ship from California and Michigan.
Shipping terms
Orders usually ship within 2 business days. All books within the US ship free of charge. Delivery is 4-14 business days anywhere in the United States.
Books ship from California and Michigan.
If your book order is heavy or oversized, we may contact you to let you know extra shipping is required.