Protection of Wind Turbine Generators Using Microcontroller-Based Applications focuses on the application of microcontrollers in the protection of wind turbine generators. The book looks at the design and implementation of a versatile digital overcurrent (OC), OV/UV, OF/UF, and negative sequence relays, and addresses the dynamic behaviour of a wind-driven induction generator (IG) connected to a power system grid through a transmission line. The transient responses of protective devices associated with the IG are also studied. Modelling of the digital relay for wind turbine generator protection using MATLAB Simulink consider most of the aerodynamic and mechanical effects that can influence instantaneous output voltage, current, and power. Coverage also includes different AC fault types, a detailed theoretical analysis of fault and protection strategy in AC fault, and the different types of fault detection algorithms to maintain power system reliability.
"synopsis" may belong to another edition of this title.
Nagwa F. Ibrahim, Ph.D.,Ph.D., is an Assistant Professor with the Department of Electrical Power and Machines, Faculty of Technology and Education, Suez University. She received her Ph.D. and MSc from Suez University and a BSc from Suez Canal University. Her research interests are focused in the areas of renewable energy sources, power system protection, power electronics, high voltage direct current (HVDC), control of power electronic converters, and electrical machine drives.
Protection of Wind Turbine Generators Using Microcontroller-Based Applications focuses on the application of microcontrollers in the protection of wind turbine generators. The book looks at the design and implementation of a versatile digital overcurrent (OC), OV/UV, OF/UF, and negative sequence relays, and addresses the dynamic behaviour of a wind-driven induction generator (IG) connected to a power system grid through a transmission line. The transient responses of protective devices associated with the IG are also studied. Modelling of the digital relay for wind turbine generator protection using MATLAB Simulink consider most of the aerodynamic and mechanical effects that can influence instantaneous output voltage, current, and power. Coverage also includes different AC fault types, a detailed theoretical analysis of fault and protection strategy in AC fault, and the different types of fault detection algorithms to maintain power system reliability.
"About this title" may belong to another edition of this title.
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In. Seller Inventory # ria9783030926304_new
Quantity: Over 20 available
Seller: Basi6 International, Irving, TX, U.S.A.
Condition: Brand New. New. US edition. Expediting shipping for all USA and Europe orders excluding PO Box. Excellent Customer Service. Seller Inventory # ABEOCT25-234638
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. 1st ed. 2022 edition NO-PA16APR2015-KAP. Seller Inventory # 26396290741
Seller: Brook Bookstore On Demand, Napoli, NA, Italy
Condition: new. Questo è un articolo print on demand. Seller Inventory # 35KRTTIQ2T
Quantity: Over 20 available
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Seller Inventory # 401167722
Quantity: 4 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. Seller Inventory # 18396290751
Quantity: 4 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Protection of Wind Turbine Generators Using Microcontroller-Based Applications focuses on the application of microcontrollers in the protection of wind turbine generators. The book looks at the design and implementation of a versatile digital overcurrent (OC), OV/UV, OF/UF, and negative sequence relays, and addresses the dynamic behaviour of a wind-driven induction generator (IG) connected to a power system grid through a transmission line. The transient responses of protective devices associated with the IG are also studied. Modelling of the digital relay for wind turbine generator protection using MATLAB Simulink consider most of the aerodynamic and mechanical effects that can influence instantaneous output voltage, current, and power. Coverage also includes different AC fault types, a detailed theoretical analysis of fault and protection strategy in AC fault, and the different types of fault detection algorithms to maintain power system reliability. 148 pp. Englisch. Seller Inventory # 9783030926304
Quantity: 2 available
Seller: Mispah books, Redhill, SURRE, United Kingdom
Condition: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Seller Inventory # ERICA80030309263036
Quantity: 1 available
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Protection of Wind Turbine Generators Using Microcontroller-Based Applications | Nagwa F. Ibrahim (u. a.) | Taschenbuch | Green Energy and Technology | xxiii | Englisch | 2023 | Springer | EAN 9783030926304 | Verantwortliche Person für die EU: Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg, juergen[dot]hartmann[at]springer[dot]com | Anbieter: preigu. Seller Inventory # 126466561
Quantity: 5 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Protection of Wind Turbine Generators Using Microcontroller-Based Applications focuses on the application of microcontrollers in the protection of wind turbine generators. The book looks at the design and implementation of a versatile digital overcurrent (OC), OV/UV, OF/UF, and negative sequence relays, and addresses the dynamic behaviour of a wind-driven induction generator (IG) connected to a power system grid through a transmission line. The transient responses of protective devices associated with the IG are also studied. Modelling of the digital relay for wind turbine generator protection using MATLAB Simulink consider most of the aerodynamic and mechanical effects that can influence instantaneous output voltage, current, and power. Coverage also includes different AC fault types, a detailed theoretical analysis of fault and protection strategy in AC fault, and the different types of fault detection algorithms to maintain power system reliability.Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg 148 pp. Englisch. Seller Inventory # 9783030926304
Quantity: 1 available