Analysis of Sub-synchronous Resonance (SSR) in Doubly-fed Induction Generator (DFIG)-Based Wind Farms (Paperback or Softback)

Mohammadpour, Hossein Ali

ISBN 10: 3031013735 ISBN 13: 9783031013737
Published by Springer 9/1/2015, 2015
New Paperback or Softback

From BargainBookStores, Grand Rapids, MI, U.S.A. Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

AbeBooks Seller since January 23, 2002

This specific item is no longer available.

About this Item

Description:

Analysis of Sub-synchronous Resonance (SSR) in Doubly-fed Induction Generator (DFIG)-Based Wind Farms. Seller Inventory # BBS-9783031013737

Report this item

Synopsis:

Wind power penetration is rapidly increasing in today's energy generation industry. In particular, the doubly-fed induction generator (DFIG) has become a very popular option in wind farms, due to its cost advantage compared with fully rated converter-based systems. Wind farms are frequently located in remote areas, far from the bulk of electric power users, and require long transmission lines to connect to the grid. Series capacitive compensation of DFIG-based wind farm is an economical way to increase the power transfer capability of the transmission line connecting the wind farm to the grid. For example, a study performed by ABB reveals that increasing the power transfer capability of an existing transmission line from 1300 MW to 2000 MW using series compensation is 90% less expensive than building a new transmission line. However, a factor hindering the extensive use of series capacitive compensation is the potential risk of subsynchronous resonance (SSR). The SSR is a condition where the wind farm exchanges energy with the electric network, to which it is connected, at one or more natural frequencies of the electric or mechanical part of the combined system, comprising the wind farm and the network, and the frequency of the exchanged energy is below the fundamental frequency of the system. This oscillatory phenomenon may cause severe damage in the wind farm, if not prevented. Therefore, this book studies the SSR phenomenon in a capacitive series compensated wind farm. A DFIG-based wind farm, which is connected to a series compensated transmission line, is considered as a case study. The book consists of two main parts: Small-signal modeling of DFIG for SSR analysis: This part presents a step-by-step tutorial on modal analysis of a DFIG-based series compensated wind farm using Matlab/Simulink. The model of the system includes wind turbine aerodynamics, a 6th order induction generator, a 2nd order two-mass shaft system, a 4th order series compensated transmissionline, a 4th order rotor-side converter (RSC) controller and a 4th order grid-side converter (GSC) controller, and a 1st order DC-link model. The relevant modes are identified using participation factor analysis. Definition of the SSR in DFIG-based wind farms: This part mainly focuses on the identification and definition of the main types of SSR that occur in DFIG wind farms, namely: (1) induction generator effect (SSIGE), (2) torsional interactions (SSTI), and (3) control interactions (SSCI).

About the Author: Hossein Ali Mohammadpour (IEEE S '2009 - M '2015) received the B.Sc. and M.Sc. degrees all in electrical engineering power systems from the Iran University of Science and Technology (IUST), Tehran, Iran, in 2006 and 2009, respectively. He also received the Ph.D. degree in electrical engineering with focus on renewable energy systems from the University of South Carolina, Columbia, SC, USA, in December 2014, where he continued as a postdoctoral fellow until March 2015. Since March 2015, he has been with the NRG Renew, Scottsdale AZ, USA as a Senior Power Systems Engineer. Dr. Mohammadpour has published over fifty papers in power systems, power electronics, and renewable energy resources in international journals and conference proceedings. His current research interests include power systems stability and control, micro-grid systems, photovoltaic, battery energy storage systems, and smart grid. Enrico Santi received the Dr. Ing. degree in electrical engineering from the University of Padua, Italy in 1988 and the M.S. and Ph.D. degrees from Caltech in 1989 and 1994, respectively. He worked as a senior design engineer at TESLAco from 1993 to 1998, where he was responsible for the development of various switching power supplies for commercial applications. Since 1998 he has been with the University of South Carolina where he is currently an associate professor in the electrical engineering department. Dr. Santi has published over one hundred and fifty papers in power electronics and modeling and simulation in international journals and conference proceedings, is co-author of two books and holds three patents. His research interests include switched-mode power converters, advanced modeling and simulation of power systems, modeling and simulation of semiconductor power devices, control of power electronics systems

"About this title" may belong to another edition of this title.

Bibliographic Details

Title: Analysis of Sub-synchronous Resonance (SSR) ...
Publisher: Springer 9/1/2015
Publication Date: 2015
Binding: Paperback or Softback
Condition: New
Book Type: Book

Top Search Results from the AbeBooks Marketplace

Seller Image

Enrico Santi
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Taschenbuch
Print on Demand

Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Wind power penetration is rapidly increasing in today's energy generation industry. In particular, the doubly-fed induction generator (DFIG) has become a very popular option in wind farms, due to its cost advantage compared with fully rated converter-based systems. Wind farms are frequently located in remote areas, far from the bulk of electric power users, and require long transmission lines to connect to the grid. Series capacitive compensation of DFIG-based wind farm is an economical way to increase the power transfer capability of the transmission line connecting the wind farm to the grid. For example, a study performed by ABB reveals that increasing the power transfer capability of an existing transmission line from 1300 MW to 2000 MW using series compensation is 90% less expensive than building a new transmission line. However, a factor hindering the extensive use of series capacitive compensation is the potential risk of subsynchronous resonance (SSR). The SSR is a condition where the wind farm exchanges energy with the electric network, to which it is connected, at one or more natural frequencies of the electric or mechanical part of the combined system, comprising the wind farm and the network, and the frequency of the exchanged energy is below the fundamental frequency of the system. This oscillatory phenomenon may cause severe damage in the wind farm, if not prevented. Therefore, this book studies the SSR phenomenon in a capacitive series compensated wind farm. A DFIG-based wind farm, which is connected to a series compensated transmission line, is considered as a case study. The book consists of two main parts: Small-signal modeling of DFIG for SSR analysis: This part presents a step-by-step tutorial on modal analysis of a DFIG-based series compensated wind farm using Matlab/Simulink. The model of the system includes wind turbine aerodynamics, a 6th order induction generator, a 2nd order two-mass shaft system, a 4th order series compensated transmissionline, a 4th order rotor-side converter (RSC) controller and a 4th order grid-side converter (GSC) controller, and a 1st order DC-link model. The relevant modes are identified using participation factor analysis. Definition of the SSR in DFIG-based wind farms: This part mainly focuses on the identification and definition of the main types of SSR that occur in DFIG wind farms, namely: (1) induction generator effect (SSIGE), (2) torsional interactions (SSTI), and (3) control interactions (SSCI).Springer Nature c/o IBS, Benzstrasse 21, 48619 Heek 68 pp. Englisch. Seller Inventory # 9783031013737

Contact seller

Buy New

US$ 25.41
Shipping: US$ 69.21
From Germany to U.S.A.

Quantity: 1 available

Add to basket

Seller Image

Enrico Santi
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Taschenbuch

Seller: AHA-BUCH GmbH, Einbeck, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Taschenbuch. Condition: Neu. Druck auf Anfrage Neuware - Printed after ordering - Wind power penetration is rapidly increasing in today's energy generation industry. In particular, the doubly-fed induction generator (DFIG) has become a very popular option in wind farms, due to its cost advantage compared with fully rated converter-based systems. Wind farms are frequently located in remote areas, far from the bulk of electric power users, and require long transmission lines to connect to the grid. Series capacitive compensation of DFIG-based wind farm is an economical way to increase the power transfer capability of the transmission line connecting the wind farm to the grid. For example, a study performed by ABB reveals that increasing the power transfer capability of an existing transmission line from 1300 MW to 2000 MW using series compensation is 90% less expensive than building a new transmission line. However, a factor hindering the extensive use of series capacitive compensation is the potential risk of subsynchronous resonance (SSR). The SSR is a condition where the wind farm exchanges energy with the electric network, to which it is connected, at one or more natural frequencies of the electric or mechanical part of the combined system, comprising the wind farm and the network, and the frequency of the exchanged energy is below the fundamental frequency of the system. This oscillatory phenomenon may cause severe damage in the wind farm, if not prevented. Therefore, this book studies the SSR phenomenon in a capacitive series compensated wind farm. A DFIG-based wind farm, which is connected to a series compensated transmission line, is considered as a case study. The book consists of two main parts: Small-signal modeling of DFIG for SSR analysis: This part presents a step-by-step tutorial on modal analysis of a DFIG-based series compensated wind farm using Matlab/Simulink. The model of the system includes wind turbine aerodynamics, a 6th order induction generator, a 2nd order two-mass shaft system, a 4th order series compensated transmissionline, a 4th order rotor-side converter (RSC) controller and a 4th order grid-side converter (GSC) controller, and a 1st order DC-link model. The relevant modes are identified using participation factor analysis. Definition of the SSR in DFIG-based wind farms: This part mainly focuses on the identification and definition of the main types of SSR that occur in DFIG wind farms, namely: (1) induction generator effect (SSIGE), (2) torsional interactions (SSTI), and (3) control interactions (SSCI). Seller Inventory # 9783031013737

Contact seller

Buy New

US$ 25.41
Shipping: US$ 70.06
From Germany to U.S.A.

Quantity: 1 available

Add to basket

Seller Image

Enrico Santi
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Taschenbuch
Print on Demand

Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Wind power penetration is rapidly increasing in today's energy generation industry. In particular, the doubly-fed induction generator (DFIG) has become a very popular option in wind farms, due to its cost advantage compared with fully rated converter-based systems. Wind farms are frequently located in remote areas, far from the bulk of electric power users, and require long transmission lines to connect to the grid. Series capacitive compensation of DFIG-based wind farm is an economical way to increase the power transfer capability of the transmission line connecting the wind farm to the grid. For example, a study performed by ABB reveals that increasing the power transfer capability of an existing transmission line from 1300 MW to 2000 MW using series compensation is 90% less expensive than building a new transmission line. However, a factor hindering the extensive use of series capacitive compensation is the potential risk of subsynchronous resonance (SSR). The SSR is a condition where the wind farm exchanges energy with the electric network, to which it is connected, at one or more natural frequencies of the electric or mechanical part of the combined system, comprising the wind farm and the network, and the frequency of the exchanged energy is below the fundamental frequency of the system. This oscillatory phenomenon may cause severe damage in the wind farm, if not prevented. Therefore, this book studies the SSR phenomenon in a capacitive series compensated wind farm. A DFIG-based wind farm, which is connected to a series compensated transmission line, is considered as a case study. The book consists of two main parts: Small-signal modeling of DFIG for SSR analysis: This part presents a step-by-step tutorial on modal analysis of a DFIG-based series compensated wind farm using Matlab/Simulink. The model of the system includes wind turbine aerodynamics, a 6th order induction generator, a 2nd order two-mass shaft system, a 4th order series compensated transmission line, a 4th order rotor-side converter (RSC) controller and a 4th order grid-side converter (GSC) controller, and a 1st order DC-link model. The relevant modes are identified using participation factor analysis. Definition of the SSR in DFIG-based wind farms: This part mainly focuses on the identification and definition of the main types of SSR that occur in DFIG wind farms, namely: (1) induction generator effect (SSIGE), (2) torsional interactions (SSTI), and (3) control interactions (SSCI). 68 pp. Englisch. Seller Inventory # 9783031013737

Contact seller

Buy New

US$ 25.41
Shipping: US$ 26.53
From Germany to U.S.A.

Quantity: 2 available

Add to basket

Seller Image

Mohammadpour, Hossein Ali|Santi, Enrico
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Kartoniert / Broschiert
Print on Demand

Seller: moluna, Greven, Germany

Seller rating 4 out of 5 stars 4-star rating, Learn more about seller ratings

Kartoniert / Broschiert. Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Wind power penetration is rapidly increasing in today s energy generation industry. In particular, the doubly-fed induction generator (DFIG) has become a very popular option in wind farms, due to its cost advantage compared with fully rated converter-based . Seller Inventory # 608129551

Contact seller

Buy New

US$ 25.63
Shipping: US$ 56.51
From Germany to U.S.A.

Quantity: Over 20 available

Add to basket

Stock Image

Mohammadpour, Hossein Ali
Published by Springer 2015-09, 2015
ISBN 10: 3031013735 ISBN 13: 9783031013737
New PF

Seller: Chiron Media, Wallingford, United Kingdom

Seller rating 4 out of 5 stars 4-star rating, Learn more about seller ratings

PF. Condition: New. Seller Inventory # 6666-IUK-9783031013737

Contact seller

Buy New

US$ 25.70
Shipping: US$ 20.27
From United Kingdom to U.S.A.

Quantity: 10 available

Add to basket

Stock Image

Mohammadpour, Hossein Ali; Santi, Enrico
Published by Springer, 2015
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Softcover

Seller: Lucky's Textbooks, Dallas, TX, U.S.A.

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Condition: New. Seller Inventory # ABLIING23Mar3113020035198

Contact seller

Buy New

US$ 26.06
Shipping: US$ 3.99
Within U.S.A.

Quantity: Over 20 available

Add to basket

Seller Image

Mohammadpour, Hossein Ali; Santi, Enrico
Published by Springer, 2015
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Softcover

Seller: GreatBookPrices, Columbia, MD, U.S.A.

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Condition: New. Seller Inventory # 44571242-n

Contact seller

Buy New

US$ 26.15
Shipping: US$ 2.64
Within U.S.A.

Quantity: Over 20 available

Add to basket

Seller Image

Mohammadpour, Hossein Ali; Santi, Enrico
Published by Springer, 2015
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Softcover

Seller: GreatBookPricesUK, Woodford Green, United Kingdom

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Condition: New. Seller Inventory # 44571242-n

Contact seller

Buy New

US$ 28.12
Shipping: US$ 19.63
From United Kingdom to U.S.A.

Quantity: Over 20 available

Add to basket

Stock Image

Mohammadpour, Hossein Ali; Santi, Enrico
Published by Springer, 2015
ISBN 10: 3031013735 ISBN 13: 9783031013737
New Softcover

Seller: Ria Christie Collections, Uxbridge, United Kingdom

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Condition: New. In English. Seller Inventory # ria9783031013737_new

Contact seller

Buy New

US$ 28.13
Shipping: US$ 15.67
From United Kingdom to U.S.A.

Quantity: Over 20 available

Add to basket

Seller Image

Mohammadpour, Hossein Ali; Santi, Enrico
Published by Springer, 2015
ISBN 10: 3031013735 ISBN 13: 9783031013737
Used Softcover

Seller: GreatBookPrices, Columbia, MD, U.S.A.

Seller rating 5 out of 5 stars 5-star rating, Learn more about seller ratings

Condition: As New. Unread book in perfect condition. Seller Inventory # 44571242

Contact seller

Buy Used

US$ 28.24
Shipping: US$ 2.64
Within U.S.A.

Quantity: Over 20 available

Add to basket

There are 4 more copies of this book

View all search results for this book