Sarker Robin (9 results)

Author: 
Refine with Advanced Search

Refine your search

  • Books (9)

to

Custom price range (US$)

to

  • Language: English

    Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2013

    3659333905 / 9783659333903

    • Softcover

    Seller: Books Puddle, Woodside, NY, U.S.A.Books Puddle

    4-star seller
    Contact seller

    Condition: New

    US$ 101.23

    US$ 3.99 shipping 
    Ships within U.S.A.

    Quantity: 4 available

    Condition: New. pp. 100.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2013

    3659333905 / 9783659333903

    • Softcover

    Seller: Mispah books, Redhill, SURRE, United KingdomMispah books

    4-star seller
    Contact seller

    Condition: Used - As new

    US$ 149.88

    US$ 33.07 shipping 
    Ships from United Kingdom to U.S.A.

    Quantity: 1 available

    Paperback. Condition: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2013

    3659333905 / 9783659333903

    • Softcover

    Seller: preigu, Osnabrück, Germanypreigu

    5-star seller
    Contact seller

    Condition: New

    US$ 230.52

    US$ 78.49 shipping 
    Ships from Germany to U.S.A.

    Quantity: 5 available

    Taschenbuch. Condition: Neu. FPGA Implementation of Low Cost Holter Monitor Using Micro-Programming | A New Approach of the Development of Long Time Heart Rate Monitoring Device | Robin Sarker (u. a.) | Taschenbuch | 100 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659333903 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Jul 2013, 2013

    3659333905 / 9783659333903

    • Softcover
    • Print on Demand

    Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

    5-star seller
    Contact seller

    Condition: New

    US$ 63.41

    US$ 25.79 shipping 
    Ships from Germany to U.S.A.

    Quantity: 2 available

    Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -ECG signal aggregates potentially precise information that could assist the clinicians in making more appropriate & timely decisions in lethal moments. Autonomous system with features of ECG characteristic extraction and heart rate measurement from such electrical response using powerful and advance methodologies are of ultimate interest. VLSI implementation of a portable Holter monitor design is presented in this work considering parallelism, distributed algorithm and re-configurable computing to allocate the DSP implementations. Lacks of bulk production opportunities have forced us to implement it in SmartFushion FPGA prototype board using Verilog micro-coding. A comparative study has been carried out to show the performance, accuracy and cost-effectiveness of the proposed hardware. This could open up a passage for the researchers to afford in lessen the production cost, for physicians and end users to draw attention in their cardiac physiology and to advocate a personal monitoring system. 100 pp. Englisch.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2013

    3659333905 / 9783659333903

    • Softcover
    • Print on Demand

    Seller: moluna, Greven, Germanymoluna

    5-star seller
    Contact seller

    Condition: New

    US$ 53.29

    US$ 54.93 shipping 
    Ships from Germany to U.S.A.

    Quantity: Over 20 available

    Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Sarker RobinRobin Sarkar has received BSc in Electronics & Communication Engg(ECE) from KUET, Bangladesh Masudul Haider Imtiaz & Mst.Rumana Aktar Sumi have received BSc & MSc from the Dept. of Applied Physics, Electronics & Communic. …

  • Language: English

    Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2013

    3659333905 / 9783659333903

    • Softcover
    • Print on Demand

    Seller: Majestic Books, Hounslow, United KingdomMajestic Books

    4-star seller
    Contact seller

    Condition: New

    US$ 102.36

    US$ 8.60 shipping 
    Ships from United Kingdom to U.S.A.

    Quantity: 4 available

    Condition: New. Print on Demand pp. 100 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam.

  • Language: English

    Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2013

    3659333905 / 9783659333903

    • Softcover
    • Print on Demand

    Seller: Biblios, frankfurt am main, HESSE, GermanyBiblios

    4-star seller
    Contact seller

    Condition: New

    US$ 107.80

    US$ 11.16 shipping 
    Ships from Germany to U.S.A.

    Quantity: 4 available

    Condition: New. PRINT ON DEMAND pp. 100.

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2013

    3659333905 / 9783659333903

    • Softcover
    • Print on Demand

    Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

    5-star seller
    Contact seller

    Condition: New

    US$ 63.41

    US$ 68.22 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - ECG signal aggregates potentially precise information that could assist the clinicians in making more appropriate & timely decisions in lethal moments. Autonomous system with features of ECG characteristic extraction and heart rate measurement from such electrical response using powerful and advance methodologies are of ultimate interest. VLSI implementation of a portable Holter monitor design is presented in this work considering parallelism, distributed algorithm and re-configurable computing to allocate the DSP implementations. Lacks of bulk production opportunities have forced us to implement it in SmartFushion FPGA prototype board using Verilog micro-coding. A comparative study has been carried out to show the performance, accuracy and cost-effectiveness of the proposed hardware. This could open up a passage for the researchers to afford in lessen the production cost, for physicians and end users to draw attention in their cardiac physiology and to advocate a personal monitoring system.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Jul 2013, 2013

    3659333905 / 9783659333903

    • Softcover
    • Print on Demand

    Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

    5-star seller
    Contact seller

    Condition: New

    US$ 230.52

    US$ 67.28 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -ECG signal aggregates potentially precise information that could assist the clinicians in making more appropriate & timely decisions in lethal moments. Autonomous system with features of ECG characteristic extraction and heart rate measurement from such electrical response using powerful and advance methodologies are of ultimate interest. VLSI implementation of a portable Holter monitor design is presented in this work considering parallelism, distributed algorithm and re-configurable computing to allocate the DSP implementations. Lacks of bulk production opportunities have forced us to implement it in SmartFushion FPGA prototype board using Verilog micro-coding. A comparative study has been carried out to show the performance, accuracy and cost-effectiveness of the proposed hardware. This could open up a passage for the researchers to afford in lessen the production cost, for physicians and end users to draw attention in their cardiac physiology and to advocate a personal monitoring system.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 100 pp. Englisch.…